| Ribbon/Toolbar (Software) | Button | Function | Error Type | Description | ||
|---|---|---|---|---|---|---|
| Ribbon/Toolbar (Software) | Button | Function | Error Type | Description | ||
| Card 515 View | Launching HydraCAD (AutoCAD Based) | None | None | None | Either: 1. \Hes\Common\ACSIZEFL.TXT is corrupted or missing 2. Installpath is set wrong, likely due to user installing twice, once to each drive? Opening |
|
| Card 348 View | Launching HydraCAD (AutoCAD Based) | None | None | None | not sure Updating Workspace |
|
| Card 413 View | Launching HydraCAD (AutoCAD Based) | None | None | None | HydraCAD font got switched to a non-HydraCAD font Cut Dimensions 52+ |
|
| Card 444 View | Plot (AutoCAD Based) | None | None | None | possible annotative scale issue. |
|
| Card 318 View | Launching HydraCAD (AutoCAD Based) | None | None | None | Virus - ALS.Bursted-B likely Opening |
|
| Card 454 View | Launching HydraCAD (AutoCAD Based) | None | None | None | STARTMODE is set to 0 Could be error, or user excluded the Start tab during installation. Start Tab |
|
| Card 458 View | Sprinklers (AutoCAD Based) | Insert Sprinkler | Define Head | Sprinkler Not Properly Configured | Before raising to 3D, the sidewall sprinklers point in the correct direction. After returning to 3D, some sidewalls have been flipped 180°
|
|
| Card 466 View | Calculations (AutoCAD Based) | Start Autocalcs | None | Runtime Error | User is missing one or more required files n/a Runtime Error 53 Miscfunc |
|
| Card 259 View | Piping (AutoCAD Based) | Riser Nipple Setup | None | None | Master drawing is not a HydraCAD drawing, so the riser nipples get displayed as the default, which is metric Xrefs |
|
| Card 342 View | Launching HydraCAD (AutoCAD Based) | None | None | None | 1. HydraCAD and Revit are not installed on C: drive and we are looking on the C: drive for it. HCAD_REVIT.dll HCAD Revit 2.5 |
|
| Card 379 View | Launching HydraCAD (AutoCAD Based) | None | None | None | PIPEX block has attributes in wrong order and/or missing HANLE attribute DRYVOL or DV HydraCAD |
|
| Card 518 View | Launching HydraCAD (AutoCAD Based) | None | None | None | requires software upgrade to a version of 55 newer than v55.01 Rev4 55 |
|
| Card 506 View | Launching HydraCAD (AutoCAD Based) | None | None | None | Changing scales |
|
| Card 123 View | Launching HydraCAD (AutoCAD Based) | None | None | None | Error 53 Missing File |
|
| Card 542 View | Launching HydraCAD (AutoCAD Based) | None | None | None | Starting up AutoCAD, the command prompt window shows messages similar to what's shown in the Error Msg/Misc box Unknown command Command line AutoCAD 2019 |
|
| Card 129 View | Calculations (AutoCAD Based) | Start Autocalcs | None | None | Calc moves very slowly or hangs and machine memory goes to 100% (all other programs seemto work fine except calcs) lag slow hang |
|
| Card 298 View | Listing (AutoCAD Based) | Start Autolist | None | None | DAO server error |
|
| Card 134 View | Calculations (AutoCAD Based) | Start Autocalcs | Finish Area | None | After 'finishing area' then exiting out of the Calc Setup screen, no HYD2 (white) reference points are inserted on the drawing Missing Reference Points No Reference Points |
|
| Card 547 View | Launching HydraCAD (AutoCAD Based) | None | None | None | Registry entries not getting setup correctly HES is not installed to the C:\ drive Missing the folder; C:\HES\HydraCAD\Ver50\common Partial uninstall of HydraCAD was done Dialog box Startup Acad 2019 |
|
| Card 277 View | Listing (AutoCAD Based) | Start Autolist | None | None | HcadBrilliant.dll is not loading properly. To see it go off again, try typing Netload at the command prompt and load HcadBrilliant. command line info. 51 |
|