Hydratec Inc.

All Cards

Page:

* On smaller devices swipe left to view hidden table data

Ribbon/Toolbar (Software) Button Function Error Type Description
Ribbon/Toolbar (Software) Button Function Error Type Description
Card 377 View Build 3D Risers (AutoCAD Based) Insert Pump None None

Discharge and or Suction inputs were typed in and not entered via the pull down. input new pump

Card 248 View Build 3D Risers (AutoCAD Based) Insert Fitting Via HydraList None Unhandled Exception

blue beam loaded on machine (a pdf writer) 3dfittings unhandled exceptio

Card 422 View 3D Modeling (AutoCAD Based) Show System Model None None

Sprinkler heads not defined in the drawing or no 3D block assigned for a sprinkler head. Going to Navis only - corrupt Persistent Model drawing? eKeyNotFound Dialog box HydraCAD

Card 241 View Listing (AutoCAD Based) Start Autolist None None

Rounding confused and thinks it is 1" 50

Card 311 View Calculations (AutoCAD Based) Calc Check Ups None None

The 'speak' feature in AutoCAD is causing the error. n/a Command prompt 51.07 r6

Card 428 View Calculations (AutoCAD Based) Reference Points None None

The sprinkler head has a Z coordinate other than zero associated to it. Hcad_refpts HydraCAD v52+

Card 502 View Piping (AutoCAD Based) Size Pipe Setup None None

Bad HCAD_ENV.INI asks for scale factor command prompt n/a

Card 170 View Listing (AutoCAD Based) Start Autolist None Unhandled Exception

Unhandled Exception - eFilerError unhandled exceptio

Card 314 View Piping (AutoCAD Based) Move Line None None

Rounding issue

Card 172 View Listing (AutoCAD Based) Start Autolist None Unhandled Exception

Unhandled exception Application does not support just-in-time (JIT) debugging. This error occurs in ALL drawing files.

Card 350 View 3D Modeling (AutoCAD Based) Show System Model None None

All SPRKDATA diameters are set to ? while cut diameters are still correct. Not sure of cause.

Card 158 View Listing (AutoCAD Based) Start Autolist None None

Command: Current text style: "HCAD" Text height: 8" nil appear in command line and no error message show No AutoLIST window appears none

Card 482 View Calculations (AutoCAD Based) Start Autocalcs Pipe Schedule None

Bad Registry Entry n/a Dialog Window HydraCALC

Card 410 View Calculations (AutoCAD Based) Figure Head Area None None

Bad setting of Acad variable

drawing area 53.02 rev 2

Card 238 View Piping (AutoCAD Based) Riser Nipple Setup None None

1. Install may not have configured properly. 2. Possibly a rogue lisp routine causing ours not to work HydraCAD v50.any

Card 447 View Calculations (AutoCAD Based) Dummy Reference Points None None

The blocks FAKEREF.DWG & FAKEREF2.DWG are not being inserted to the drawing. Unknown reason because the code should do that automatically. All tests in office work fine. n/a Dialog Box 53.03

Card 375 View Piping (AutoCAD Based) Size Pipe Setup None None

Unknown 2013 V52

Card 295 View 3D Modeling (AutoCAD Based) Show System Model None None

Cannot read the HydraPipe dictionary Hydrapipes dictionary needs to be overwritten solid pipes 3d modeling v50+

Card 455 View Piping (AutoCAD Based) Edit Riser Nipples None None

Using AutoCAD's ROTATE command will not rotate a VP HydraCAD v52+

Card 167 View Listing (AutoCAD Based) Start Autolist None None

Some threaded branch lines are not being tagged automatically as expected. Automatic Line Tags are missing after running AutoLIST. none