Hydratec Inc.

Need to save a card for later?

Create a bookmark folder in your browser of choice (Chrome, Firefox...), and save individual cards in your bookmarks to view here later.

AutoCAD Based Piping (Ribbon/Toolbar/Location)

Button: Schedule Sizes

Description:

Path/File Read Error

Solutions:

Cause:

Error occurs when "Add Calculation Fittings" is used when running AutoCALC the first time after a new install. A registry entry for one of the Pipe Schedule properties is not set in the registry. (The Pipe Schedule is connected to fittings definitions.)

Solution:

1 -Close HydraCAD - Open HydraCALC - Select Pipe Schedule-Pick ALL drop down arrows (open/close) and Exit. 2 - Open HydraCAD and start AutoCALC - Select the Sizing button to open the pipe schedule screen. Pick ALL drop down arrows (open/close) and Exit. Complete an AutoCALC process. Registry entries are set & the command should work

Updated: April 15, 2024, 12:40 p.m. Created: March 1, 2019, midnight