Ribbon/Toolbar (Software) Button Function Error Type Description
Ribbon/Toolbar (Software) Button Function Error Type Description
Card 485 View Launching HydraCAD (AutoCAD Based) None None None

The customer cannot activate the software. Each users name and email needs to be registered in the customers Autodesk Account in order to use the Autodesk Desktop Subscriptions. registration

Card 140 View Piping (AutoCAD Based) Schedule Sizes None None

no error but all values are blank in the pipe schedule

Card 528 View Launching HydraCAD (AutoCAD Based) None None None

Win10 update broke it (per AutoDesk) Graphics Win10

Card 521 View Launching HydraCAD (AutoCAD Based) Paper Space Tabs None None

Graphics Problem P.S. Tabs

Card 477 View Launching HydraCAD (AutoCAD Based) Install None None

Bad AutoCAD install or missing registry keys n/a AutoCAD 2017

Card 264 View Launching HydraCAD (AutoCAD Based) Save None None

Something has disabled the QSAVE. Unknown cause but usually happens after AutoCalc Command in progres Command Prompt AutoCAD 2009,2010

Card 386 View Cleanup (AutoCAD Based) Draw Pretty Pipes None None

1. Corrupt external data 2. 3D Head Block set wrong. show fittings HydraCAD V5x

Card 512 View Launching HydraCAD (AutoCAD Based) None None None

Windows 10 update n/a Dialog box Acad 2016+

Card 317 View Launching HydraCAD (AutoCAD Based) None None Unhandled Exception

.NET Framework not installed properly Unhandled Exceptio Opening

Card 252 View Launching HydraCAD (AutoCAD Based) Plotting None None

Viewport created in frozen of off layer Viewports

Card 459 View Launching HydraCAD (AutoCAD Based) Install None None

Corrupt install of Acad 2015 Hkey_Classes Windows v53

Card 322 View Launching HydraCAD (AutoCAD Based) None None None

Multiple flavors of AutoCAD on same machine. The first one gets only partially configured. The paths are set right, but the SMaRT stuff is not configured Opening Multiple

Card 39 View HydraCALC (Revit Based) Hydraulic Calculations Continue None

HydraCALC input screen is blank or this message box appears 

Card 441 View Launching HydraCAD (AutoCAD Based) None None None

Drawing from GC or one of the trades was drawn in MicroStation was converted from a DGN file to a DWG file. The DGN linetypes bloat the DWG file. n/a file size 2014 or older

Card 130 View Calculations (AutoCAD Based) Reference Points None None

No error, but inserting a HYD hydraulic reference point will use the coordinates as the node ID. If you check the properties of the block, the VALUE & LOCATION values are swapped.

Card 505 View Launching HydraCAD (AutoCAD Based) None None None

User had admin rights but does not have full control of the HES folder dialog box dialog box Acad 2017

Card 463 View Launching HydraCAD (AutoCAD Based) None None None

1. Missing profile 2. Bad registry entry 3. User does not have Admin privileges Unable to find profile Installation Acad 2015~

Card 457 View Launching HydraCAD (AutoCAD Based) None None None

Bad update. These Files are missing system folder dependencies of HydexVB64 or HydexVB3: MFC100u.dll MSVCR100.dll MSVCP100.dll Because of this, no pass can be given nor does security work on any product. (64-bit products may work while 32-bit products don't or vice versa) Opening

Card 496 View HydraTools (AutoCAD Based) Rebuild HydraCAD Layers None None

Corrupt drawing RBL AutoCAD n/a

Card 393 View Launching HydraCAD (AutoCAD Based) None None None

If it's a stand-alone version of AutoCAD, there may be a previously installed network version of AutoCAD which is confusing Acad as to where it should be looking for its licence. n/a Splash screen AutoCAD 2012