Ribbon/Toolbar (Software) Button Function Error Type Description
Ribbon/Toolbar (Software) Button Function Error Type Description
Card 378 View Launching HydraCAD (AutoCAD Based) None None None

AutoCAD MEP 2013 has new swtiches set in shortcut that we don't Opening AutoCAD MEP

Card 465 View Piping (AutoCAD Based) Stacked Riser Nipples None None

stacked rn connects to first pipe and misses second pipe leaving a pipe going up to nowhere. this is caused by a floor boundary with a negative elevation adn computer generated VP

Card 395 View Calculations (AutoCAD Based) Add Calculation Fittings None None

Error 52 trying to insert fittings for calculations. Error 71 disk not ready error trying to use the sizing button. error 52 or 71

Card 421 View Launching HydraCAD (AutoCAD Based) None None None

Files or folders in the C:\HES are set to 'read-only' n/a Toolbars AutoCAD 2015

Card 443 View Launching HydraCAD (AutoCAD Based) None None None

Move or Copy Slow Graphics

Card 292 View Launching HydraCAD (AutoCAD Based) Paper Space None None

In a paper space viewport, certain blocks or dimensions do not appear, even though the layer is ON and set to Plot in Current Viewport

It may appear as if the layer is not showing up, but it is really certain items in the layer

Card 419 View Launching HydraCAD (AutoCAD Based) None None None

If the file path listed is "C:\HES\Hydracad\Ver50\Programs\...", then you need to add the HES folder to the Trusted Folders list. n/a Dialog Box Acad 2015

Card 357 View Launching HydraCAD (AutoCAD Based) None None None

1. models on a project have been made using different versions of HydraCAD - RevitLink Revit

Card 406 View Launching HydraCAD (AutoCAD Based) Update None None

Windows user may not have admin rights n/a Windows Dialog Box

Card 396 View Launching HydraCAD (AutoCAD Based) None None None

Install Path Registry entry is incorrect or missing.

Card 268 View Launching HydraCAD (AutoCAD Based) Purge None Fatal Error

A sprinkler head is drawn in space and is not connect to anything. When the drawing is raised a Hydrafitting (cap) is placed on the head. if the purge command is invoked it will cause a fatal error. Fatal error Purge V51

Card 387 View Launching HydraCAD (AutoCAD Based) None None None

During the AutoCAD 2014 installation, the user unchecked the option to install Autodesk 360. Even after the install, 360 was still there, so it was uninstalled. AutoCAD Acad 2014

Card 509 View Head Selector (Standalone) None None None

While multiple PDFs are being opened in the PDF viewer, HydraHEADS displays a message box; "There were 'x' PDFs for this sprinkler...". The user clicked OK on the dialog box before the PDF viewer had a chance to open *ALL* the PDFs. Runtime Error dialog box 50.21.4

Card 438 View Cleanup (AutoCAD Based) Cloud None None

The cloud command does not finish correctly, when user right-clicks to close it. Cloud Command

Card 479 View Launching HydraCAD (AutoCAD Based) None None None

HydraCAD Installation issue n/a n/a n/a

Card 119 View Piping (AutoCAD Based) Schedule Sizes None None

Path/File Read Error

Card 452 View Launching HydraCAD (AutoCAD Based) None None None

the sevices for the AutoDESK licensing has been turned off

Card 532 View Launching HydraCAD (AutoCAD Based) None None None

Unknown F8 command n/a AutoCAD 2017

Card 523 View Launching HydraCAD (AutoCAD Based) None None None

change in autocad version change in the network change in your connection to the network error 15.570.0 Will not open any

Card 127 View Launching HydraCAD (AutoCAD Based) Layer None None

Error adding Layers to Database