Hydratec Inc.

AutoCAD Based Cards

Total: 697

Page:

* On smaller devices swipe left to view hidden table data

Ribbon/Toolbar (Software) Button Function Error Type Description
Ribbon/Toolbar (Software) Button Function Error Type Description
Card 781 View Sprinklers (AutoCAD Based) Select Sprinkler Choose Part Number Sprinkler Not Properly Configured

While using the 'Choose Part Number' button to open HydraHEAD Selector and retrieive its description and part number, you get the errors below;

Runtime Error 713, Application-defined or object-defined error

Sprinkler not properly configured.  Please re-select using 'Choose part'

Card 385 View Sprinklers (AutoCAD Based) Bay Space None Bad Argument

Keyboard alias "BS"

Bayspace preview is not lining up the sprinklers evenly.  Or Bayspace stops working with a "Bad Argument Type 2D/3D point error." message.

Card 458 View Sprinklers (AutoCAD Based) Insert Sprinkler Define Head Sprinkler Not Properly Configured

Before raising to 3D, the sidewall sprinklers point in the correct direction.  After returning to 3D, some sidewalls have been flipped 180°

Card 308 View Sprinklers (AutoCAD Based) Insert Sprinkler Head Block Definition None

Text is the wrong size due to DIMTXT setting. Possibly caused by changing annotative scales. V50/V51

Card 524 View Sprinklers (AutoCAD Based) Insert Sprinkler None None

missing data files in \HES\HYDRACAD\Ver50\DATA\SETUP Selecting

Card 446 View Sprinklers (AutoCAD Based) Insert Sprinkler None None

The BLKRDEF1 sprinkler definition block was revised to include the 3D Head Block name and Head Adjustment (drop/sprig take out) attributes. The drawing has an older BLDRDEF1 sprinkler definition block inserted before the update. HydraCAD V52 V53

Card 448 View Sprinklers (AutoCAD Based) Insert Sprinkler Define Head None

Unknown but HydraHeads is having problems using Nitro Pro to view the PDF files n/a Viewing PDF 50.19.3

Card 384 View Sprinklers (AutoCAD Based) Head Schedule None None

If the user runs the sprinkler head schedule, the dry volume text window will not appear. DRYVOLU or DV HydraCAD 52.03 r1

Card 261 View Sprinklers (AutoCAD Based) Insert Sprinkler New Symbol None

most commonly caused by dual monitor setup and laptops. NOTES: in the solution below ; the "R17.x or R18.x" string points to the version of cad you are using. R17.0 = ACAD07 R17.1 = ACAD08 R17.2 = ACAD09 After selecting "profiles" you will then pick the profile you are currently using. lock up Select new symbol Open Browse

Card 507 View Sprinklers (AutoCAD Based) Insert Sprinkler None None

Missing application n/a Choose Part Number n/a