Advanced Search
Total results: 1243
* On smaller devices swipe left to view hidden table data
Ribbon/Toolbar (software) | Button | Function | Error Type | Description | ||
---|---|---|---|---|---|---|
Ribbon/Toolbar (software) | Button | Function | Error Type | Description | ||
Card 572 View | HydraCALC (AutoCAD Based) | None | None | Runtime Error | When opening HydraCalc v50, you get Run-time error '13' Type mismatch OK The calc program will open but you cannot open any jobs or do anything in the window. Runtime error 13 |
|
Card 35 View | HydraCALC (Revit Based) | Define Supply | Pick | None | Too many Water Supplies! error message when using the Define Water Supply function |
|
Card 856 View | HydraCALC Sizer (Standalone) | Open | None | Runtime Error | When trying to open HydraCALC Sizer, a 'run-time error 76', Path not found error pops up and the program doesn't open. |
|
Card 695 View | HydraLIST (Standalone) | Test Point | None | None | When HydraLIST attempted to open, windows detected an error in one of the DLL's which was created by the installation of a previous application. This error launched the Miscrosoft Installer which tried to repair the problem but the previous application did not leave enough informatio on the drive to camplete the repair. Missing DAO.MSI |
|
Card 692 View | HydraLIST (Standalone) | None | None | None | The install path in the registry is incorrect. The user changed the Master Data location to the server, then changed it back to the C:\ drive and forced the data load, causing the files in the setup folder to be deleted as hydralist opened. In one case, copying over MASK.MDB didn't help, as a Runtime Error 70 (Permission Denied) was displayed, and MASK.MDB was gone from the folder. Runtime Error 53 |
|
Card 36 View | HydraLIST (Revit Based) | Create Stocklist | Return To Revit | None | Line/Main annotations do not populate with Line/Main numbers after running the calculation. |
|
Card 834 View | HydraLIST (Standalone) | HydraVIEW | None | None | No error. Pick Setup and nothing happens. |
|
Card 753 View | HydraLIST (Standalone) | None | None | None | Can not find the paired scanner host can not recieve signal. Error Sending Data to keyboard. Buffer lost connect to host. |
|
Card 643 View | HydraCALC (AutoCAD Based) | Calculate | None | None | Attempting to calculate the project from the Pre-Calc Questions screen, it looks like a quick flash and nothing happens. Check the version by going to Help|About HydraCALC. If you get a Run-time error '453' then see the Error card regarding that issue. n/a n/a |
|
Card 594 View | HydraCALC (AutoCAD Based) | Print Final | None | None | none No setup dialog Hydracalc50 |