Ribbon/Toolbar (software) | Button | Function | Error Type | Description | ||
---|---|---|---|---|---|---|
Ribbon/Toolbar (software) | Button | Function | Error Type | Description | ||
Card 157 View | 3D Modeling (AutoCAD Based) | Show System Model | None | None | blank or incomplete job path job path |
|
Card 258 View | Hangers (AutoCAD Based) | Insert One Hanger | None | None | Hanger length attribute is missing. The hanger inserts only the assembly number even if the HIDE NUMBER box is checked in the Hanger Setup. A V45 hanger block is in the drawing. It has only one attribute value & can display only the number. HydraCAD v50 |
|
Card 263 View | Steel (AutoCAD Based) | Structure Elevations | None | None | when placing a TOS defline and a item is picked to place the Tos defline. If the item has a Z coordinate then this can be assinged the TOS block. the defline will be a 0 but the blocks will be elevated (although it looks normal) this will usually raise once and then the error will occur even if you put a new defline in. tos id missing |
|
Card 359 View | Build 3D Risers (AutoCAD Based) | Insert Fitting Via HydraList | None | None | Unknown NET.framework Insert interface |
|
Card 445 View | Build 3D Risers (AutoCAD Based) | Insert Fitting Via HydraList | None | None | Bug in software. The pipe created in the MAINS tab of HydraLIST is Metric but HydraCAD believes the pipe is Imperial, therefore it scales it up by 25.4 n/a n/a Hcad v52+ |
|
Card 353 View | Build 3D Risers (AutoCAD Based) | Insert Fitting Via HydraList | None | None | Outlets are missing from a main that has been listed in HydraLIST. The section ID has a space or other special chacter in the name. |
|
Card 247 View | Hangers (AutoCAD Based) | Insert One Hanger | None | None | 1. HydraCAD v45 SMaRT drawing in HydraCAD v50 bad argument HydraCAD v50 |
|
Card 1023 View | Sprinklers (AutoCAD Based) | FSC Setup | None | Error During Load | When attempting to create a Flexible Connection you get these errors; Then this; Could not find file FSC-INSERTDEFLINE.txt |
|
Card 401 View | HydraCALC (Standalone) | Print Final | None | None | 1. The info sheet has symbols when it is expecting a number or blank, i.e. "Rack Sprinkler Demand" is N/A instead of blank or 0. Error:Bad Argument 52.02+ |
|
Card 1216 View | 3D Modeling (AutoCAD Based) | Persistent Model | None | None | When viewing your Persistent Model drawing, you see the clamshells/Pacman/bracket for the riser nipples/vertial pipes
|