Hydratec Inc.

AutoCAD Based Cards

Total: 700

Page:

* On smaller devices swipe left to view hidden table data

Ribbon/Toolbar (Software) Button Function Error Type Description
Ribbon/Toolbar (Software) Button Function Error Type Description
Card 418 View Build 3D Risers (AutoCAD Based) Insert Fitting Via Parts Tree None Unhandled Exception

When trying to insert a 3D fitting via the Fittings Parts Tree, the user gets the error message;

Microsoft .NET Framework
Unhandled Exception has occurred...
Argument 'Key' is not a valid value

When user clicks CONTINUE and tries to use the INSERT button to insert a fitting, another dialog box pops up

INSERT FITTINGS
Unhandled Exception...
Index was out of range.  Must be non-negative and less than the size of the collection.  Parameter name: index

Card 265 View Build 3D Risers (AutoCAD Based) Insert Ski Pole None None

Unknown *invalid_ skipole* 3D Risers HydraCAD v50

Card 1358 View 3D Modeling (AutoCAD Based) S3D - Raise to 3D None None

When closing a drawing in 3D, and later re-opening and returning to 2D, some of the drawing symbols show up looking like outlines (Hangers, Sprinklers, etc)


Card 1313 View 3D Modeling (AutoCAD Based) S3D - Raise to 3D None Error Inserting To Block Table

When raising to 3D, you get the following error;

Error inserting to block table HEAD#/HH## to head dictionary

Card 1281 View 3D Modeling (AutoCAD Based) Show System Model None None

Sprinkler heads not defined in the drawing or no 3D block assigned for a sprinkler head. Going to Navis only - corrupt Persistent Model drawing? eKeyNotFound Dialog box HydraCAD

Card 1272 View 3D Modeling (AutoCAD Based) Show Model Errors None Crash

When raising to 3D, AutoCAD crashes with no error, no warning, it just closes.

You can test this by closing all open drawings then starting a new drawing using the Hydratec template, "Hydracad Imperial Default".

Draw one pipe 10' long (LN command). 

Place a length & 2" diameter on it (SZP command)

Place a 10' AFF elevation mark on it (AFF command)

Start the process of raising to 3D (S3D command).  It will then crash out without warning around step 2 (something about sprinkler heads).

Card 1216 View 3D Modeling (AutoCAD Based) Persistent Model None None

When viewing your Persistent Model drawing, you see the clamshells/Pacman/bracket for the riser nipples/vertial pipes

 

 

Card 1158 View 3D Modeling (AutoCAD Based) Check Elevation None None

Card 1106 View 3D Modeling (AutoCAD Based) Show System Model None Unhandled Exception

While attempting to raise to 3D, you get this error message;

 

Exception Occured at AddURLToHyperlinks::HydraHeads

 

 

The drawing will still raise to 3D but you may not have sprinkler heads visible.

 

(TYPE_E_CANTLOADLIBRARY)

679327F1-F31E-488D-8FBC-124C4F6F588E

DAO32ServerLib.DaoComObj

Card 1081 View 3D Modeling (AutoCAD Based) Show System Model None Please Switch To System Model

When attempting to create a 3D model, you get the error; Please switch to System Model to Annotate Drops and Sprigs plus

System.NullReferenceException: Object reference not set to an instance of an object

at HCADexports.RevitConversion.create_hydrapipes_from_db()

at HCADexports.RevitConversion.create_hydrafittings_from_db(List'1 pipes, List'1 heads)

 

Page: