Card 447 View Calculations (AutoCAD Based) Dummy Reference Points None None

The blocks FAKEREF.DWG & FAKEREF2.DWG are not being inserted to the drawing. Unknown reason because the code should do that automatically. All tests in office work fine. n/a Dialog Box 53.03

Card 352 View Calculations (AutoCAD Based) Figure Head Area Dialog Box None

APQ block is not in the block table FATAL ERROR Dialog Box HydraCAD v52

Card 449 View Calculations (AutoCAD Based) Add Calculation Fittings None None

Error occurs when "Add Calculation Fittings" is used when running AutoCALC the first time after a new install. A registry entry for one of the Pipe Schedule properties is not set in the registry. (The Pipe Schedule is connected to fittings definitions.) error 75

Card 358 View Calculations (AutoCAD Based) Start Autocalcs None None

Machine is set up to generate old-style (pre-AutoCAD 14) polylines. Flowing Heads Remote Area

Card 273 View Calculations (AutoCAD Based) Start Autocalcs None None

The regisrty BOUNDS entry cuts off the bottom of the dialog box. V50

Card 415 View Calculations (AutoCAD Based) Reference Points None None

A non HydraCAD REFPT block was inserted into the drawing. Most likely a SprinkCAD version is in there. Hcad_refpts HydraCAD v52+

Card 64 View Calculations (AutoCAD Based) Start Autocalcs None None

Step 1a.6 - attaching nodes Hangs pause pauses locks freezes

Card 341 View Calculations (AutoCAD Based) Start Autocalcs None None

Unable to write files to hard drive HES folders (among others) were not 'active' in that they appeared faint yellow when looking at them in Windows Explorer/My Computer AutoCalc/Checkups

Card 327 View Calculations (AutoCAD Based) Start Autocalcs None None

Pipe Elevation Deflines without elevation block attached AutoCalc

Card 105 View Calculations (AutoCAD Based) Start Autocalcs None Runtime Error

Running an AutoCALC, it hangs at step 1a.3 while attaching fittings and you get a Runtime Error 5

 