Ribbon/Toolbar (Software) Button Function Error Type Description
Ribbon/Toolbar (Software) Button Function Error Type Description
Card 363 View Sprinklers (AutoCAD Based) Insert Sprinkler None None

Autocad variables align x hair w\clg 2013

Card 239 View Sprinklers (AutoCAD Based) Insert Sprinkler None None

Possibly a rogue lisp routine causing ours not to work HydraCAD v50.any

Card 501 View Sprinklers (AutoCAD Based) FSC Setup None None

Registry bug. When the FSC command is used for the VERY first time, if the drawing is saved to a drive other than the local drive, you *may* get this error.

Card 548 View Sprinklers (AutoCAD Based) FSC Setup None None

Various issues with the DETAILS layer.

Card 1301 View Riser Nipples (AutoCAD Based) Edit Riser Nipples None Other

When selecting a vertical pipe/riser nipple hydrapipe, the PROPERTIES window shows "no selection" instead of "hydrapipe"

 

You may notice that you cannot use the 'change length' command (CL) or cannot rotate riser nipple (RRT)

 

Card 1174 View Riser Nipples (AutoCAD Based) Riser Nipple Type None Other

After editing riser nipples/vertical pipes with the CRN command, the indicator diamonds reappear

 

 

Even if you restart the command and cancel, they remain

 

Card 1101 View Riser Nipples (AutoCAD Based) Edit Riser Nipples Change Riser Nipple Type None

Glyphs used to indicate the component type (Line/Main/Armover/Underground) that riser nipples are to be listed as remain on drawing even after command is closed

Card 1212 View Ribbon Click (AutoCAD Based) None None Fatal Error

Selecting any button from the AutoCAD ribbon creates the fatal error.  Typing or using a toolbar does not create the error. 

AutoCAD Error Aborting

FATAL ERROR: Unhandled e0434352h Exception at 6C6CCF19h

Sometimes followed by;

AutoCAD Error-abort Error Handler Re-Entered. Exiting now.

The program is missing Tool Palettes and Ribbons.
The drawing may briefly open and then crash.

Card 1285 View Plot (AutoCAD Based) Plot None Missing Pipe

When using 'Publish selected layouts' or doing a batch plot in AutoCAD 2024, the riser nipple/vertial pipe does not display correctly.  It'll either be missing outright or a proxy bounding box will be in its place.  If you plot a single sheet, it works fine.

 

 

AutoCAD 2024 batch plot

'

 

AutoCAD 2024 single plot

 

 

 

Card 1197 View Plot (AutoCAD Based) Plot None None

When plotting two viewports, one with center-to-center lengths, and the other with cut lenghts, the riser nipples/vertical pipes will show both, even if your layout tab looks fine.

LAYOUT TAB

PLOT PREVIEW