Hydratec Inc.

Need to save a card for later?

Create a bookmark folder in your browser of choice (Chrome, Firefox...), and save individual cards in your bookmarks to view here later.

AutoCAD Based Plot (Ribbon/Toolbar/Location)

Button: Plot Error Type: Missing pipe

Description:

When using 'Publish selected layouts' or doing a batch plot in AutoCAD 2024, the riser nipple/vertial pipe does not display correctly.  It'll either be missing outright or a proxy bounding box will be in its place.  If you plot a single sheet, it works fine.

 

 

AutoCAD 2024 batch plot

'

 

AutoCAD 2024 single plot

 

 

 

Solutions:


1.
Cause:

Unknown but seems to be related to AutoCAD 2024 batch plots only

Solution:

When the Publish window opens, uncheck the option for 'Publish in background'.  This should make the vertical pipes plot properly.

 

 

Thanks Doug P!


2.
Cause:

Unknown but seems to be related to AutoCAD 2024 batch plots only

Solution:

Two suggestions would be;

1. Open the drawing in an older version of AutoCAD and try the batch plot there

 

2. Using INSERTCLASSIC, insert the drawing into a new HydraCAD template and reattempt the batch plot in Acad 2024.  Below is the result of the plot after inserting it into a new drawing.

 

Updated: June 20, 2024, 10:24 a.m. Created: Feb. 12, 2024, 3:43 p.m.