Ribbon/Toolbar (Software) Button Function Error Type Description
Ribbon/Toolbar (Software) Button Function Error Type Description
View (card-306) Calculations (AutoCAD Based) Start Autocalcs None None

Setting incorrect

View (card-273) Calculations (AutoCAD Based) Start Autocalcs None None

The regisrty BOUNDS entry cuts off the bottom of the dialog box. V50

View (card-240) Calculations (AutoCAD Based) Start Autocalcs Calc Area # None

Possibly a crash when dialog is minimzed For example - with autocalc - view flowing paths crashes, then the AutoCALC dialog box is minimized HydraCad v50

View (card-143) Calculations (AutoCAD Based) Start Autocalcs None None

x Zero length pipes found in system model YES will cancel... No will allow...

View (card-141) Calculations (AutoCAD Based) Start Autocalcs Calc Area # Message Box

System seems to hang at this step, but eventually shows the error;

Hydraulic Calculation - The system flow demand of ####.## exceeds the maximum rated flow as indicated in the Pump Curve for the pump with the inlet of PI and outlet of PO.

 

The calculation will not continue Calculation failed for an unknown reason

May not be 1a.3 or 2.3, could be anywhere along here.

View (card-138) Calculations (AutoCAD Based) Start Autocalcs Calc Area # Missing File

 

File name asked for does NOT exist

FitExch.dat 1A.1

View (card-137) Calculations (AutoCAD Based) Start Autocalcs Finish Area None

Unhandled Exception When clicking the 'Finish Area #' button at the completion of the AutoCALC process, a diablob box pops up; "Object reference not set to an Instance of an object" Just in time JIT Just-in-time System.NullReferenceException: CalcingNameSpace.AutoCalcForm.redButton

View (card-136) Calculations (AutoCAD Based) Calc Check Ups None None

Running AutoCALC checkups on a drawing causes AutoCAD to crash out AutoCAD Application has stopped working A problem caused the program to stop working correctly. Windows will close the program and notify you if a solution is available.

View (card-135) Calculations (AutoCAD Based) Start Autocalcs None None

During the AutoCALC process, it gets hung up at step 5a.3b. 

Re-Ordering Pipe Paths - Phase 2

 

View (card-134) Calculations (AutoCAD Based) Start Autocalcs Finish Area None

After 'finishing area' then exiting out of the Calc Setup screen, no HYD2 (white) reference points are inserted on the drawing Missing Reference Points No Reference Points