AutoCAD Based (Calculations)
Total: 79
Page:
* On smaller devices swipe left to view hidden table data
Ribbon/Toolbar (Software) | Button | Function | Error Type | Description | ||
---|---|---|---|---|---|---|
Ribbon/Toolbar (Software) | Button | Function | Error Type | Description | ||
View (card-1206) | Calculations (AutoCAD Based) | Start Autocalcs | None | Freezes | When running the AutoCALC process, it hangs at step 2.4e "Re-Loading Calculated Data - AutoPeaking Data" May also happen around steps 2.3, 2.4a, 2.4b, 2.4c, and 2.4d
|
|
View (card-1184) | Calculations (AutoCAD Based) | Start Autocalcs | None | Runtime Error | When running AutoCALC, the process stops around step 2.4c and you get a Run-time error 457, "This key is already associated with an element of this collection
|
|
View (card-1129) | Calculations (AutoCAD Based) | Start Autocalcs | None | None | When starting the AutoCALC process, you get an error like this; You are missing a --- refPoint to complete a JUMP. Clicking OK should allow the process to continue on |
|
View (card-1105) | Calculations (AutoCAD Based) | Hydraulic Demand | None | Bad Argument | When trying to insert a Hydraulic demand block (Compact/Standard/Expanded) (IHD command) and after selecting the .WXF file to use;
You get the error message; Error: bad argument type: numberp: DATAFILE And the command kicks you out. |
|
View (card-1103) | Calculations (AutoCAD Based) | Start Autocalcs | None | Unhandled Exception | When starting the AutoCALC process, you get the error; Unhandled exception has occurred in a componenet in your application eOnLockedLayer
|
|
View (card-952) | Calculations (AutoCAD Based) | Start Autocalcs | Finish Area | Missing Pipe | After running the AutoCALC process on a long grid system, you realize some of the gridlines in the middle didn't get picked up.
|
|
View (card-885) | Calculations (AutoCAD Based) | Start Autocalcs | None | Runtime Error | Runtime Error 6 when Attaching Fittings Fitting is a RED. COUPLING @ node DAB0C connected to pipes D9FE8 :D9FE2. Trying to run a auto calc from a drawing. How do I find the referenced pipes? |
|
View (card-846) | Calculations (AutoCAD Based) | Start Autocalcs | Calc Area # | J19380 | Just after starting the Autocalc Settings, the dialog box as shown below pops up and the process stops. Something went wrong! Error Code J19380 |
|
View (card-840) | Calculations (AutoCAD Based) | Start Autocalcs | Finish Area | None | AutoCALC is creating extra node points where there shouldn't be. In the image below, node 45 shouldn't be created as there's neither a flowing head nor a change in diameter at that point.
'extra node' 'extra ref point' 'extra reference point' 'refpt' |
|
View (card-831) | Calculations (AutoCAD Based) | Start Autocalcs | None | Runtime Error | Caclulating Total Lengths... Runtime Error "13" Type mis-match |
Page: