Ribbon/Toolbar (Software) Button Function Error Type Description
Ribbon/Toolbar (Software) Button Function Error Type Description
View (card-1206) Calculations (AutoCAD Based) Start Autocalcs None Freezes

When running the AutoCALC process, it hangs at step 2.4e "Re-Loading Calculated Data - AutoPeaking Data"

May also happen around steps 2.3, 2.4a, 2.4b, 2.4c, and 2.4d

 

 

View (card-1184) Calculations (AutoCAD Based) Start Autocalcs None Runtime Error

When running AutoCALC, the process stops around step 2.4c and you get a Run-time error 457, "This key is already associated with an element of this collection

 

 

View (card-1129) Calculations (AutoCAD Based) Start Autocalcs None None

When starting the AutoCALC process, you get an error like this;

You are missing a --- refPoint to complete a JUMP. 

Clicking OK should allow the process to continue on

View (card-1105) Calculations (AutoCAD Based) Hydraulic Demand None Bad Argument

When trying to insert a Hydraulic demand block (Compact/Standard/Expanded) (IHD command) and after selecting the .WXF file to use;

 

You get the error message;

Error: bad argument type: numberp: DATAFILE

And the command kicks you out.

View (card-1103) Calculations (AutoCAD Based) Start Autocalcs None Unhandled Exception

When starting the AutoCALC process, you get the error; Unhandled exception has occurred in a componenet in your application

eOnLockedLayer

 

View (card-952) Calculations (AutoCAD Based) Start Autocalcs Finish Area Missing Pipe

After running the AutoCALC process on a long grid system, you realize some of the gridlines in the middle didn't get picked up.

 

View (card-885) Calculations (AutoCAD Based) Start Autocalcs None Runtime Error

Runtime Error 6 when Attaching Fittings

Fitting is a RED. COUPLING @ node DAB0C connected to pipes D9FE8 :D9FE2.

Trying to run a auto calc from a drawing.  How do I find the referenced pipes?

View (card-846) Calculations (AutoCAD Based) Start Autocalcs Calc Area # J19380

Just after starting the Autocalc Settings, the dialog box as shown below pops up and the process stops.  

Something went wrong!  Error Code J19380

View (card-840) Calculations (AutoCAD Based) Start Autocalcs Finish Area None

AutoCALC is creating extra node points where there shouldn't be.  In the image below, node 45 shouldn't be created as there's neither a flowing head nor a change in diameter at that point.

 

'extra node'

'extra ref point'

'extra reference point'

'refpt'

View (card-831) Calculations (AutoCAD Based) Start Autocalcs None Runtime Error

Caclulating Total Lengths...

Runtime Error "13"

Type mis-match