Hydratec Inc.

Advanced Search

Total results: 10

Page:

* On smaller devices swipe left to view hidden table data

Ribbon/Toolbar (software) Button Function Error Type Description
Ribbon/Toolbar (software) Button Function Error Type Description
Card 274 View Piping (AutoCAD Based) Riser Nipple Setup None None

Riser Nipple center to center and cut dimension properties are both on the same layer. Turn off SPRKDATB and cut dimension does not turn off. SPRKDATB layer did not exist when riser nipple was inserted or a V45 template was used to start the V50 or V51 drawing or drawing was converted from V45 to V50 or V51 HydraCAD v5x.any

Card 259 View Piping (AutoCAD Based) Riser Nipple Setup None None

Master drawing is not a HydraCAD drawing, so the riser nipples get displayed as the default, which is metric Xrefs

Card 238 View Piping (AutoCAD Based) Riser Nipple Setup None None

1. Install may not have configured properly. 2. Possibly a rogue lisp routine causing ours not to work HydraCAD v50.any

Card 424 View Piping (AutoCAD Based) Riser Nipple Setup Dialog Box None

Avast Virus Checker believes the file has a virus n/a Dialog Box Acad 2015

Card 1020 View Piping (AutoCAD Based) Riser Nipple Setup None None

When inserting a VP, the text shows double white text, not white and magenta.  Using the CEL or CUL command still shows the double text

Card 279 View Piping (AutoCAD Based) Riser Nipple Setup None None

bad UCS setting select vp

Card 243 View Piping (AutoCAD Based) Riser Nipple Setup None None

Hydrapipes apparently use Standard as their Style and the menu macro no longer changes Standard, only the Style named Hcad

Card 349 View Piping (AutoCAD Based) Riser Nipple Setup None None

Visual style set to something other than 2dWireframe

Card 300 View Piping (AutoCAD Based) Riser Nipple Setup None None

1. the v50 drawing does not have the block vp defined

Card 910 View Piping (AutoCAD Based) Riser Nipple Setup None Fatal Error

When trying to insert a riser nipple/vertical pipe, you get a FATAL ERROR:  Unhandled Access Violation. 592A00h or 8B2A00h