Ribbon/Toolbar (software) | Button | Function | Error Type | Description | ||
---|---|---|---|---|---|---|
Ribbon/Toolbar (software) | Button | Function | Error Type | Description | ||
Card 1058 View | Collaborate (AutoCAD Based) | Create Revit Mep Link To System Model | None | Unexpected Error | TWO SYMPTOMS: Drawing fittings and pipe look disjointed, like that time an alien team of scientists were performing out-of-phase medical experiments on the Voyager crew. Or, on the way into Revit, you get this error; Error (must be addressed in order to continue) Revit has experienced an unexpected error. The operation has been cancelled to protect your project from corruption Deleted element When reporting the error, you may see this; Hashtable head_table, Hashtable FLXpipeTable, List '1 listFtgs, flexpipes PipeTypeInfo ptInfo |
|
Card 365 View | Collaborate (AutoCAD Based) | Create Revit Mep Link To System Model | None | Unhandled Exception | 1. mismatched files HCADexports.dll and HcadAquaFlex_50_1.arx Unhandled Exception Make Revit Content HCAD Revit 4.0.0.3 |
|
Card 1026 View | Collaborate (AutoCAD Based) | Create Revit Mep Link To System Model | None | Import Error | While importing an AutoCAD model into Revit, you get errors listed below;
|
|
Card 497 View | Collaborate (AutoCAD Based) | Create Revit Mep Link To System Model | None | None | Sprinkler heads were not properly defined with a part number within the HydraCAD drawing. Therefore, Revit used a default sprinkler head symbol which happened to be a pendent sprinkler symbol. Revit |
|
Card 948 View | Collaborate (AutoCAD Based) | Create Revit Mep Link To System Model | None | None | Missing commands on Add in for HydraCAD when trying to generate a RevitLink conversion |
|
Card 412 View | Collaborate (AutoCAD Based) | Create Revit Mep Link To System Model | None | None | AutoCAD entities too far out in space for revit to handle |
|
Card 370 View | Collaborate (AutoCAD Based) | Create Revit Mep Link To System Model | None | None | 1. dry pendent sprinkler is defined in the drawing and cannot be generated as Revit content Retrieve content Revit revit Link 4-2 |
|
Card 411 View | Collaborate (AutoCAD Based) | Create Revit Mep Link To System Model | None | None | Unknown, but likely that creation of Revit content will still be accomplished. |
|
Card 403 View | Collaborate (AutoCAD Based) | Create Revit Mep Link To System Model | None | None | Revit Link was not installed with Admin Rights |