Hydratec Inc.

Need to save a card for later?

Create a bookmark folder in your browser of choice (Chrome, Firefox...), and save individual cards in your bookmarks to view here later.

Standalone HydraCALC (Location)

Button: Open Error Type: Runtime Error

Description:

When trying to open HydraCALC, the user gets a Runtime Error 5, "Invalid Procedure Call or Argument"

Solutions:


1.
Cause:

Water connections entered in water supply window doesn't match the water supply entered in the input

Solution:

The connection point reference point must match source reference point


2.
Cause:

A crash or unexpected close of HydraCALC has corrupted one of the data files

 

-OR-

 

Elements of the Hydratec install are spread among multiple drives.  

 

-OR-

 

Saved install path location mismatched in registry

Solution:

Check the folder location "local drive:\HES\Common\Ver50\" for the file "User.ini". It has likely become corrupt.  

Delete the corrupt file then copy a good one from another user or contact Hydratec for a copy or see solution #2 of this HydraCARD;

https://hydracards.hydratecinc.com/cards/card-1021 

 

-OR-

 

Check all other local drives to see if more than one /HES folder has been created. Re-install all Hydratec applications to a single drive (Make sure to get rid of the other HES folders).

 

-OR-

 

InstallPath set to wrong drive letter. Manually change InstallPath key in

Computer\HKEY_LOCAL_MACHINE\SOFTWARE\HYDRATEC\Ver50 to be proper letter, (i.e. C: or D:)

also change InstallPath in:

Computer\HKEY_LOCAL_MACHINE\SOFTWARE\WOW6432Node\HYDRATEC\Ver50

Updated: Sept. 20, 2022, 9:54 a.m. Created: Aug. 13, 2020, 4:53 p.m.