Standalone HydraCALC (Location)
Description:
When trying to open HydraCALC, the user gets a Runtime Error 5, "Invalid Procedure Call or Argument"
Water connections entered in water supply window doesn't match the water supply entered in the input
The connection point reference point must match source reference point
A crash or unexpected close of HydraCALC has corrupted one of the data files
-OR-
Elements of the Hydratec install are spread among multiple drives.
-OR-
Saved install path location mismatched in registry
Check the folder location "local drive:\HES\Common\Ver50\" for the file "User.ini". It has likely become corrupt.
Delete the corrupt file then copy a good one from another user or contact Hydratec for a copy or see solution #2 of this HydraCARD;
https://hydracards.hydratecinc.com/cards/card-1021
-OR-
Check all other local drives to see if more than one /HES folder has been created. Re-install all Hydratec applications to a single drive (Make sure to get rid of the other HES folders).
-OR-
InstallPath set to wrong drive letter. Manually change InstallPath key in
Computer\HKEY_LOCAL_MACHINE\SOFTWARE\HYDRATEC\Ver50 to be proper letter, (i.e. C: or D:)
also change InstallPath in:
Computer\HKEY_LOCAL_MACHINE\SOFTWARE\WOW6432Node\HYDRATEC\Ver50