Need to save a card for later?
Create a bookmark folder in your browser of choice (Chrome, Firefox...), and save individual cards in your bookmarks to view here later.
Standalone HydraLIST (Location)
Description:
The computer has been setup to get data updates from a master location on a network. The computer is then disconnected form the network. The user rights force an error that is not by passable. By design the update from the master data location should be by passed if the network is not connected. error 52 52
Runtime Error 52
1. connect network or 2. pick Start Run enter regedit pick the plus sign in front of KEY_CURRENT_USER pick the plus sign in front of Software pick the plus sign in front of Hydratec pick the plus sign in front of HydraLIST pick the plus sign in front of Ver50 pick on MasterDataSite Double click on "Site" set Value Data to na pick OK Double click on "Force" set Value Data to False pick OK Close window Open HydraLIST