AutoCAD Based Launching HydraCAD (Ribbon/Toolbar/Location)

Description:

Registry entries not getting setup correctly HES is not installed to the C:\ drive Missing the folder; C:\HES\HydraCAD\Ver50\common Partial uninstall of HydraCAD was done Dialog box Startup Acad 2019

Solutions:

Cause:

Registry entries not getting setup correctly HES is not installed to the C:\ drive Missing the folder; C:\HES\HydraCAD\Ver50\common Partial uninstall of HydraCAD was done

Solution:

See if running HydraCADv5xFIX fixes the issue, this file should fix the registry issues. 2. If the HES drive is not the C:\ drive, using the Registry Editor, confirm that Computer\HKEY_LOCAL_MACHINE\SOFTWARE\HYDRATEC\Ver50 >> InstallPath is pointing to the correct drive. Fix if necessary. Run the HydraCADv5xFIX 3. If the user installed a newer HydraCAD then later UNinstalled their older version of HydraCAD. a. Make a backup of the HES folder b. Completely uninstall Hydratec c. Delete the HES folder but keep the backup d. Re-install Hydratec programs

Updated: March 18, 2024, 2:48 p.m. Created: March 1, 2019, midnight