Hydratec Inc.

Need to save a card for later?

Create a bookmark folder in your browser of choice (Chrome, Firefox...), and save individual cards in your bookmarks to view here later.

AutoCAD Based Calculations (Ribbon/Toolbar/Location)

Button: Start Autocalcs Function: Calc Area # Error Type: Runtime Error

Description:

Step 1A.1 - Runtime error 13 type mismatch

Solutions:

Cause:

Cause:

1. Source point and feed piping are outside of steel limits, the only defline is a BTS. does not know how to assign elevations to source point. (more........ scroll down)

2. Old style water supply with pump possibly caused by converting from V45

3. There is a RN with a 0 length

4. Non legal symbol in a reference point (/,\ < >, etc.)

Solution:

Solution:

1. Put an Aff specification on the feed piping and change the riser vertical pipe to be computer generated

2. Erase water supply and pump, reinsert a new one

3. Correct the RN

4. Erase and reinsert reference point without symbols.

Updated: Aug. 14, 2023, 2:24 p.m. Created: March 1, 2019, midnight