AutoCAD Based Listing (Ribbon/Toolbar/Location)

Button: Start Autolist Error Type: Unhandled Exception

Description:

Unhandled exception Application does not support just-in-time (JIT) debugging. This error occurs in ALL drawing files.

Solutions:

Cause:

List appears to run most of the way through, but model stays in 3D and HydraLIST does not open after the unhandled exception. The HydraLIST file has only partial job information. Drop Annotation Options had blank entries.

Solution:

Pick the Define Drops & Sprigs button. Select the ANNOTATIONS OPTIONS button in the dialog box. Text Height and Angle may be blank and must have a number value assigned. Verify that there are Input values for all entries.

Updated: Feb. 27, 2024, 3:07 p.m. Created: March 1, 2019, midnight