Hydratec Inc.

All Cards

Page:

* On smaller devices swipe left to view hidden table data

Ribbon/Toolbar (Software) Button Function Error Type Description
Ribbon/Toolbar (Software) Button Function Error Type Description
Card 363 View Sprinklers (AutoCAD Based) Insert Sprinkler None None

Autocad variables align x hair w\clg 2013

Card 240 View Calculations (AutoCAD Based) Start Autocalcs Calc Area # None

Possibly a crash when dialog is minimzed For example - with autocalc - view flowing paths crashes, then the AutoCALC dialog box is minimized HydraCad v50

Card 287 View Build 3D Risers (AutoCAD Based) Insert Fitting Via HydraList None None

bad setting in cad variable DISPSILH pipe display

Card 436 View Collaborate (AutoCAD Based) Navisworks Toolkit Export Piping to Navis None

Date set in "options" of navis do not match version of Autocad Missing objects Navis

Card 114 View Calculations (AutoCAD Based) Remote Area Select Polyline None

When attempting to convert an existing polyline to the Remote Area polyline, you get the following error when selecting a pline. Error: Automation Error. Key not found Command:

Card 337 View Piping (AutoCAD Based) Size Pipe Setup None None

Some pipe sizes have the diameter and length attributes switched in their order

Card 179 View Listing (AutoCAD Based) Start Autolist None None

Error No Tags Found No Tags Found

Card 145 View Listing (AutoCAD Based) Start Autolist None Unhandled Exception

Unhandled exception: eNullobjectId Application does not support just-in-time (JIT)

Card 116 View Listing (AutoCAD Based) Listing Check Ups None Unhandled Exception

When attempting to run AutoLIST checkups and selecting a boundary, user gets an error similar to the one below; [Exception in fs_util.arx ARX Command] Unhandled Exception C00000005 (Access Violation Writing 0x9485ad10) at address 7720F86h OR Unhandled Exception in FS_UTIL.ARX and/or ADS request.

Card 177 View Listing (AutoCAD Based) Start Autolist None None

Field is too small to accept the amount of data you attempted to add. Try inserting or pasting less data. Runtime Error

Card 340 View Hangers (AutoCAD Based) Create 3D Hangers None None

Create 3D Hangers command did not created 3D hangers for the #01B hanger assembly but it did for all other hanger assembly types. #01B 3D hanger information is not in the DAT file. HydraCAD v50

Card 476 View Collaborate (AutoCAD Based) Navisworks Toolkit Export Piping to Navis None

When in the Pipe Model Settings window (Setup window in Navis toolkit), the user cleared the text box for "Layer Name prefix" Dialog Box Acad 2016+

Card 460 View 3D Modeling (AutoCAD Based) Show System Model None None

Unknown n/a Pipe diameters 53+

Card 182 View Listing (AutoCAD Based) Start Autolist None None

Run-time error 70 Permission denied Runtime Error 70

Card 293 View Hangers (AutoCAD Based) Insert One Hanger None None

??? Connection Failed listing tags

Card 367 View Hangers (AutoCAD Based) Create 3D Seismic Braces None None

older or bad file inserting 52

Card 168 View Listing (AutoCAD Based) Start Autolist None None

HydraLIST input for pipe type is reported as "FITTING" and not the letter of the requested pipe type. See the "Error Circles" on drawing at the fitting where the listing instruction expects to have couplings cut in. (such as Grooved Elbow or Grooved Tee) 1 Typical Error Circle Message: Coupling expected but not found for a '????????'. Insert coupling or change fabrication method 2 Typical Error Circle Message: Takeout of fitting does not match takeout expected for a '????????'. Change fitting or fabrication method

Card 499 View Cleanup (AutoCAD Based) Draw Pretty Pipes None Unhandled Exception

Pretty Pipes requires line type TRACKS. This line type is missing from the drawing. Unhandled Except. v50

Card 334 View Build 3D Risers (AutoCAD Based) Insert Fitting Via Parts Tree None None

1) Inserting 3d fittings is very slow & you must hit enter several times to get through the command. Must pick Enter or OK for each fitting. 2) Could also be related to an AutoCAD drawing variable setting.

Card 599 View Calculations (AutoCAD Based) Start Autocalcs Calc Area # None

Screen shows calcing Pump, then getting error 53. Pump calc not calcing Run time 53

Page: