Hydratec Inc.

All Cards

Page:

* On smaller devices swipe left to view hidden table data

Ribbon/Toolbar (Software) Button Function Error Type Description
Ribbon/Toolbar (Software) Button Function Error Type Description
Card 467 View Persistent Model (AutoCAD Based) Export None None

The lines or mains do not get the pretty pipes applied. The layer is all lower case. Lines or Mains missing

Card 163 View Listing (AutoCAD Based) Listing Check Ups None None

During checkups, the process abruptly ends and reports "Exception occurred" on the command prompt Command prompt

Card 381 View Listing (AutoCAD Based) New Tag None None

??? Error when picking NewTag button. Connection Failed listing tags

Card 449 View Calculations (AutoCAD Based) Add Calculation Fittings None None

Error occurs when "Add Calculation Fittings" is used when running AutoCALC the first time after a new install. A registry entry for one of the Pipe Schedule properties is not set in the registry. (The Pipe Schedule is connected to fittings definitions.) error 75

Card 244 View Piping (AutoCAD Based) Edit Riser Nipples None None

Insert RN , it asks for Higher\lower pipe then dissapears. Probalble bad configuration dissapear

Card 429 View Build 3D Risers (AutoCAD Based) Insert Fitting Via Parts Tree None None

Corrupt #741 drawing. 26090000xx.DWG Fatal Error n/a AutoCAD 2014

Card 347 View Hangers (AutoCAD Based) Create 3D Hangers None None

3D hangers appear 'on the floor' Hangers

Card 602 View HydraCALC (Standalone) None None None

weird characters in autocalc summary 1?#0 view summary fonts

Card 336 View Piping (AutoCAD Based) Insert One RN None None

Riser Nipple cut dimension changed to the wrong value after going into the 3D System Model. The Riser Nipple show the wrong takeout value for the sp TakeOut & ep TakeOut properties. This was caused by the SHOW FITTINGS command. HydraCAD v5x.any

Card 290 View 3D Modeling (AutoCAD Based) Show System Model None None

1. Can happen when creating a 3d model by picking a system boundary/boundaries. Bad/corrupt system boundary. 2d to 3d button 3d modeling v50+

Card 358 View Calculations (AutoCAD Based) Start Autocalcs None None

Machine is set up to generate old-style (pre-AutoCAD 14) polylines. Flowing Heads Remote Area

Card 364 View Build 3D Risers (AutoCAD Based) Insert Fitting Via HydraList None None

May not on current update 52.01b or later 3D Details V52

Card 294 View 3D Modeling (AutoCAD Based) Show System Model None None

The Show System Model process shows all pipes and fittings including riser nipples. However, Riser Nipples do not display in Realistic or Conceptual Visual Styles. HydraCAD V50

Card 365 View Collaborate (AutoCAD Based) Create Revit Mep Link To System Model None Unhandled Exception

1. mismatched files HCADexports.dll and HcadAquaFlex_50_1.arx Unhandled Exception Make Revit Content HCAD Revit 4.0.0.3

Card 407 View 3D Modeling (AutoCAD Based) Check Elevation None None

Bad TOS defline block(s) in the drawing or an object drawn in the DEFLINESSTRUCTURE layer (eg. Line, circle, rectangle, etc). Dialog box Dialog Box Hcad v53

Card 188 View Listing (AutoCAD Based) Start Autolist None None

Process could not delete database file. Close HydraLIST project and Retry Retry Cancel n/a

Card 304 View Build 3D Risers (AutoCAD Based) Insert Fitting Via HydraList None None

microsoft .net framework error Program cannot set defaults. Registry key may be missing. 3dfittings Unhandled Exception

Card 273 View Calculations (AutoCAD Based) Start Autocalcs None None

The regisrty BOUNDS entry cuts off the bottom of the dialog box. V50

Card 534 View Build 3D Risers (AutoCAD Based) Insert Fitting Via HydraList None None

Missing registry entries n/a Dialog Box

Card 508 View Cleanup (AutoCAD Based) Draw Pretty Pipes None Unhandled Exception

User drew own entities in FLEXPIPE Layer. That layer is only to be used by HydraCAD Unhandled Except. V50