All Cards
* On smaller devices swipe left to view hidden table data
| Ribbon/Toolbar (Software) | Button | Function | Error Type | Description | ||
|---|---|---|---|---|---|---|
| Ribbon/Toolbar (Software) | Button | Function | Error Type | Description | ||
| Card 106 View | Calculations (AutoCAD Based) | Calc Check Ups | None | None | Duplicate Reference Points with jump detour |
|
| Card 402 View | Calculations (AutoCAD Based) | Start Autocalcs | None | None | Process is crashing out because an old vertical pipe block is in the drawing DRYVOL or DV HydraCAD V50+ |
|
| Card 384 View | Sprinklers (AutoCAD Based) | Head Schedule | None | None | If the user runs the sprinkler head schedule, the dry volume text window will not appear. DRYVOLU or DV HydraCAD 52.03 r1 |
|
| Card 243 View | Piping (AutoCAD Based) | Riser Nipple Setup | None | None | Hydrapipes apparently use Standard as their Style and the menu macro no longer changes Standard, only the Style named Hcad |
|
| Card 150 View | Listing (AutoCAD Based) | Start Autolist | None | None | V45 converted to V50, the hangers show up in list but no cut dimensions on drawing |
|
| Card 160 View | Listing (AutoCAD Based) | Start Autolist | None | None | nil |
|
| Card 470 View | 3D Modeling (AutoCAD Based) | Show System Model | None | None | The last sprinkler head setup as sprigs on sloped pipe will most likely show a cap length shorter than the 'flat' length. For instance, a 3" capped pipe is returning from 3D as 2" rather than a longer length. n/a Plan View n/a |
|
| Card 372 View | Couplings (AutoCAD Based) | Insert Couplings | None | None | Program has become "tired" |
|
| Card 549 View | 3D Modeling (AutoCAD Based) | Show System Model | None | None | Drawing zooms out to expected isometric view as if 3D System Model has been completed. No 3D Pipe can be found. Unknown cause No 3D Pipe Seen All |
|
| Card 270 View | 3D Modeling (AutoCAD Based) | Show System Model | None | None | 1. Video Driver out of Date -or- 2. AutoCAD MEP has a .dbx file interfering with our drawing HydraCAD |
|
| Card 272 View | 3D Modeling (AutoCAD Based) | Show System Model | None | None | The CURRENT LAYER in the drawing is LOCKED. Show System Model process stops on Step 13 of 28 while adding RN Fittings to the drawing. Picking the 2D Switch to Edit Mode button removes the Hydrapipes and the riser nipples. Show System Model HydraCAD V51 |
|
| Card 519 View | 3D Modeling (AutoCAD Based) | Switch To Edit Mode | None | None | AutoCAD Support file search path is pointing to extra, incorrect paths. Usually caused by migrating settings during install rather than running a clean install. n/a HydraCAD v53 - Acad 2016 |
|
| Card 398 View | 3D Modeling (AutoCAD Based) | Switch To Edit Mode | None | None | 1. Important layers locked or frozen. 2. User had OPHEAD block in ACC1 layer Internal error |
|
| Card 373 View | 3D Modeling (AutoCAD Based) | Show System Model | None | None | issue with drawing dictionary making model |
|
| Card 261 View | Sprinklers (AutoCAD Based) | Insert Sprinkler | New Symbol | None | most commonly caused by dual monitor setup and laptops. NOTES: in the solution below ; the "R17.x or R18.x" string points to the version of cad you are using. R17.0 = ACAD07 R17.1 = ACAD08 R17.2 = ACAD09 After selecting "profiles" you will then pick the profile you are currently using. lock up Select new symbol Open Browse |
|
| Card 101 View | Piping (AutoCAD Based) | Size Pipe Setup | None | None | Value of 6 is not valid |
|
| Card 423 View | 3D Modeling (AutoCAD Based) | Show System Model | None | None | May have to do with sprinkler heads not defined in the drawing Exception Occured Dialog box HydraCAD |
|
| Card 633 View | Piping (AutoCAD Based) | Schedule Sizes | None | Runtime Error | When trying to open the pipe scheduler, the user gets a Runtime Error 7, Out of memory Runtime Error 7 |
|
| Card 537 View | 3D Modeling (AutoCAD Based) | Show System Model | None | None | 1. Important layers such as SPRKDAT1 through SPRKDAT4 are lower case instead of upper case. 3d modeling |
|
| Card 286 View | Piping (AutoCAD Based) | Schedule Sizes | None | None | Possible bad ceiling defline |
|