All Cards
* On smaller devices swipe left to view hidden table data
Ribbon/Toolbar (Software) | Button | Function | Error Type | Description | ||
---|---|---|---|---|---|---|
Ribbon/Toolbar (Software) | Button | Function | Error Type | Description | ||
Card 173 View | Listing (AutoCAD Based) | Start Autolist | None | None | Change requested in table not successful. Change data in fields or fields containing duplicate data. Error 3022 |
|
Card 115 View | Calculations (AutoCAD Based) | None | None | Runtime Error | Runtime Error 380. After raising to 3D then then selecting the pipe types to apply the schedule to, the error message pops up when the HydraCALC Pipe Scheduler tool is supposed to appear. Press OK at the error message then ESC when the command asks to select a pipe. |
|
Card 97 View | Calculations (AutoCAD Based) | Reference Points | None | None | 1. Inserting a hydraulic reference point doesn't erase an existing ref point at the same location 2. New ref points in HydraCALC are not using the values of the HYD ref points. |
|
Card 498 View | Build 3D Risers (AutoCAD Based) | Insert Fitting Via HydraList | None | None | Dialog box is not appearing |
|
Card 516 View | Piping (AutoCAD Based) | Edit Riser Nipples | None | None | Bad coding 2018 Riser Nipples V55 |
|
Card 178 View | Listing (AutoCAD Based) | Start Autolist | None | Unhandled Exception | Unhandled exception E was erased Unhandled exception |
|
Card 256 View | 3D Modeling (AutoCAD Based) | Check Elevation | None | None | Bad support path or cad not configured for V50.
|
|
Card 369 View | Calculations (AutoCAD Based) | Figure Head Area | None | Unhandled Exception | When returning from 3D view, the drawing's current layer becomes Layer 0 (zero). Unhandled Exception Dialog Box v51 v52 |
|
Card 583 View | All products (Security and Licensing) | None | None | Error 99 | Error 99. Hydratec Security Versioning Error. You do not have access to this version of this product. |
|
Card 363 View | Sprinklers (AutoCAD Based) | Insert Sprinkler | None | None | Autocad variables align x hair w\clg 2013 |
|
Card 240 View | Calculations (AutoCAD Based) | Start Autocalcs | Calc Area # | None | Possibly a crash when dialog is minimzed For example - with autocalc - view flowing paths crashes, then the AutoCALC dialog box is minimized HydraCad v50 |
|
Card 287 View | Build 3D Risers (AutoCAD Based) | Insert Fitting Via HydraList | None | None | bad setting in cad variable DISPSILH pipe display |
|
Card 436 View | Collaborate (AutoCAD Based) | Navisworks Toolkit | Export Piping to Navis | None | Date set in "options" of navis do not match version of Autocad Missing objects Navis |
|
Card 114 View | Calculations (AutoCAD Based) | Remote Area | Select Polyline | None | When attempting to convert an existing polyline to the Remote Area polyline, you get the following error when selecting a pline. Error: Automation Error. Key not found Command: |
|
Card 337 View | Piping (AutoCAD Based) | Size Pipe Setup | None | None | Some pipe sizes have the diameter and length attributes switched in their order |
|
Card 179 View | Listing (AutoCAD Based) | Start Autolist | None | None | Error No Tags Found No Tags Found |
|
Card 145 View | Listing (AutoCAD Based) | Start Autolist | None | Unhandled Exception | Unhandled exception: eNullobjectId Application does not support just-in-time (JIT) |
|
Card 116 View | Listing (AutoCAD Based) | Listing Check Ups | None | Unhandled Exception | When attempting to run AutoLIST checkups and selecting a boundary, user gets an error similar to the one below; [Exception in fs_util.arx ARX Command] Unhandled Exception C00000005 (Access Violation Writing 0x9485ad10) at address 7720F86h OR Unhandled Exception in FS_UTIL.ARX and/or ADS request. |
|
Card 177 View | Listing (AutoCAD Based) | Start Autolist | None | None | Field is too small to accept the amount of data you attempted to add. Try inserting or pasting less data. Runtime Error |
|
Card 340 View | Hangers (AutoCAD Based) | Create 3D Hangers | None | None | Create 3D Hangers command did not created 3D hangers for the #01B hanger assembly but it did for all other hanger assembly types. #01B 3D hanger information is not in the DAT file. HydraCAD v50 |
Page: