AutoCAD Based Piping (Ribbon/Toolbar/Location)

Button: Insert One RN

Description:

Riser Nipple cut dimension changed to the wrong value after going into the 3D System Model. The Riser Nipple show the wrong takeout value for the sp TakeOut & ep TakeOut properties. This was caused by the SHOW FITTINGS command. HydraCAD v5x.any

Solutions:

Cause:

Riser Nipple cut dimension changed to the wrong value after going into the 3D System Model. The Riser Nipple show the wrong takeout value for the sp TakeOut & ep TakeOut properties. This was caused by the SHOW FITTINGS command.

Solution:

Go to the SMaRTools Options - In the Pipe and Fittings Rendering tab: UNCHECK SHOW FITTINGS IN MODEL or edit the DEFAULT MAIN CONNECTIONS to the correct type of material that you want to use for the model. Note Unchecking the Show Fittings in Model will generate the System Model quicker. This will make AutoCALC & AutoLIST quicker also.

Updated: Feb. 14, 2024, 3:26 p.m. Created: March 1, 2019, midnight