Hydratec Inc.

All Cards

Page:

* On smaller devices swipe left to view hidden table data

Ribbon/Toolbar (Software) Button Function Error Type Description
Ribbon/Toolbar (Software) Button Function Error Type Description
Card 602 View HydraCALC (Standalone) None None None

weird characters in autocalc summary 1?#0 view summary fonts

Card 336 View Piping (AutoCAD Based) Insert One RN None None

Riser Nipple cut dimension changed to the wrong value after going into the 3D System Model. The Riser Nipple show the wrong takeout value for the sp TakeOut & ep TakeOut properties. This was caused by the SHOW FITTINGS command. HydraCAD v5x.any

Card 169 View Listing (AutoCAD Based) Start Autolist None Dao Error

Call from Autolist::CleanUpLinesDatabase(lineDB) DAO error DAO error

Card 392 View Couplings (AutoCAD Based) Insert Couplings None None

Drawing is saved on a server or the cloud.

Card 290 View 3D Modeling (AutoCAD Based) Show System Model None None

1. Can happen when creating a 3d model by picking a system boundary/boundaries. Bad/corrupt system boundary. 2d to 3d button 3d modeling v50+

Card 358 View Calculations (AutoCAD Based) Start Autocalcs None None

Machine is set up to generate old-style (pre-AutoCAD 14) polylines. Flowing Heads Remote Area

Card 364 View Build 3D Risers (AutoCAD Based) Insert Fitting Via HydraList None None

May not on current update 52.01b or later 3D Details V52

Card 294 View 3D Modeling (AutoCAD Based) Show System Model None None

The Show System Model process shows all pipes and fittings including riser nipples. However, Riser Nipples do not display in Realistic or Conceptual Visual Styles. HydraCAD V50

Card 365 View Collaborate (AutoCAD Based) Create Revit Mep Link To System Model None Unhandled Exception

1. mismatched files HCADexports.dll and HcadAquaFlex_50_1.arx Unhandled Exception Make Revit Content HCAD Revit 4.0.0.3

Card 407 View 3D Modeling (AutoCAD Based) Check Elevation None None

Bad TOS defline block(s) in the drawing or an object drawn in the DEFLINESSTRUCTURE layer (eg. Line, circle, rectangle, etc). Dialog box Dialog Box Hcad v53

Card 188 View Listing (AutoCAD Based) Start Autolist None None

Process could not delete database file. Close HydraLIST project and Retry Retry Cancel n/a

Card 304 View Build 3D Risers (AutoCAD Based) Insert Fitting Via HydraList None None

microsoft .net framework error Program cannot set defaults. Registry key may be missing. 3dfittings Unhandled Exception

Card 273 View Calculations (AutoCAD Based) Start Autocalcs None None

The regisrty BOUNDS entry cuts off the bottom of the dialog box. V50

Card 534 View Build 3D Risers (AutoCAD Based) Insert Fitting Via HydraList None None

Missing registry entries n/a Dialog Box

Card 508 View Cleanup (AutoCAD Based) Draw Pretty Pipes None Unhandled Exception

User drew own entities in FLEXPIPE Layer. That layer is only to be used by HydraCAD Unhandled Except. V50

Card 415 View Calculations (AutoCAD Based) Reference Points None None

A non HydraCAD REFPT block was inserted into the drawing. Most likely a SprinkCAD version is in there. Hcad_refpts HydraCAD v52+

Card 171 View Listing (AutoCAD Based) Start Autolist None None

Head block definition is correct but the wrong sprinkler head thread size is reported in HydraLIST. Wrong welded outlet size for sprinkler heads are reported in HydraLIST. head sprinkler outlet size thread none

Card 175 View Listing (AutoCAD Based) Start Autolist None Runtime Error

Run-time error 5 swap wizards

Card 397 View 3D Modeling (AutoCAD Based) Show System Model None None

1. Heads not defined show flexdrops

Card 152 View Listing (AutoCAD Based) Start Autolist None None

drops/sprigs do not get listed none