Card 755 View HydraLIST (Standalone) None None None

UAC is set to high 339

Card 779 View HydraLIST (Standalone) Process None None

the Rod_Length.dat in the hes\hydlist\ver50\data\setup folder has bad data this is an optional file used to optimize the rod used on a project Without the file the length of rod is just the total length of the rod rounded up to the nearest foot

Card 680 View HydraLIST (Standalone) Test Point None Runtime Error

Cause 1 Ultimate Landscaping software was loaded on the computer. Cause2 load the drivers from a CD for the HP7550 printer Runtime Error 3447

Card 678 View HydraLIST (Standalone) Test Point None Runtime Error

Printer Drive or other software with the printer for a Sharp AR-M280 N. Runtime Error 429

Card 684 View HydraLIST (Standalone) Error Check Section Mains Runtime Error

Unknown Runtime Error 94 94

Card 667 View HydraLIST (Standalone) Edit None Runtime Error

Unknown Runtime Error 13 13

Card 772 View HydraLIST (Standalone) Search Database None Runtime Error

Windows regional setting is causing a problem with the search database function in HydraLIST. Run-time 3708 3708 50.21.5

Card 768 View HydraLIST (Standalone) None None None

some how the automatic update setup was turned on Not sure how the customer can get this set. 10

Card 764 View HydraLIST (Standalone) None None Runtime Error

Mising or damaged registry entries. Runtime Error 76

Card 742 View HydraLIST (Standalone) Test Point None Runtime Error

New build of hydexVB3.dll requires windows files MFC100u.dll, MSVCR100.dll, & MSVCP100.dll to be in the windows/system32 or windows/syswow64 folder. Runtime Error 48 or 53 50.00.20