Standalone HydraLIST (Location)

Button: Test Point Error Type: Runtime Error

Description:

Mismatch Miscrosoft dll's Cause by one or all of the following: Update to Windows Adding or removing software Runtime Error 523

Solutions:

Cause:

Data binding Dll vb5bd.dll could not be loaded

Solution:

Check version Number of each off the dll's listed below. If some are missing replace them with dll's of the same version Number. if not all have matching versions then replace the files with the bad version. If you have some Visual Basic 5.0 and some from Visual Basic 6.0 replace the odd ones. DAO files are in the ProgramFiles/common/microsoftshare/DAO folder the remaining are in the system32 folder Visual Basic 5.0 Files and Version Numbers: DAO350.dll 3.50.3602.0 MSJet35.dll 3.50.3602.4 MSJInt35.dll 3.50.3602.5 MSJtEr35.dll 3.50.3602.0 MSRD2x35.dll 3.50.3602.0 MSRepl35.dll 3.50.3602.0 MSVCRT40.dll 4.10.6038 or later VB5DB.dll 5.00.3724 VBAJet32.dll 5.0.7122 Visual Basic 6.0 Files and Version Numbers: DAO350.dll 3.51.1608.0 ExpSrv.dll 6.0.8167 MSJet35.dll 3.51.0623.4 MSJInt35.dll 3.51.0623.0 MSJtEr35.dll 3.51.0623.0 MSRepl35.dll 3.51.0623.0 MSRD2x35.dll 3.51.0623.0 MSVCRT40.dll 4.21.0000 or later VB5DB.dll 6.00.8169 VBAJet32.dll 6.1.8167

Updated: Sept. 19, 2022, 9:59 a.m. Created: March 1, 2019, midnight