Ribbon/Toolbar (Software) | Button | Function | Error Type | Description | ||
---|---|---|---|---|---|---|
Ribbon/Toolbar (Software) | Button | Function | Error Type | Description | ||
Card 723 View | HydraLIST (Standalone) | Process | None | Runtime Error | There is a line or main named X Runtime 50.18.0 or older |
|
Card 722 View | HydraLIST (Standalone) | Process | None | None | Unknown - but happens on Windows 7 machines Can also be caused by: A main or line ID that begins with the letter X. A main or line ID that contains no input data. SldReports MFC see card 2 for other v50.18 or older |
|
Card 721 View | HydraLIST (Standalone) | Process | None | Runtime Error | length of pipe in data input is longer than the stock length for lines in the pipe length tables. runtime error 105 HydrLIST Select |
|
Card 720 View | HydraLIST (Standalone) | Test Point | None | Runtime Error | The system was set update the setup data when entering the program. One of the files in the hes\hydlist\ver50\data\setup folder was either locked or read only runtime error 75 75 |
|
Card 719 View | HydraLIST (Standalone) | None | None | None | Invalid or missing vaule in registry registry error v50? |
|
Card 718 View | HydraLIST (Standalone) | Test Point | None | Runtime Error | Run-time error 3051... The Microsoft Jet database engine cannot open the file Can happen when opening HydraLIST or Head Selector 50.00.14+ |
|
Card 717 View | HydraLIST (Standalone) | Process | None | None | 1. weld slip flange is on the end of the pipe at fitting position 1 2. fitting size starts with a 100 |
|
Card 716 View | HydraLIST (Standalone) | Test Point | None | Runtime Error | Run-time Error 339 "Component tab32x30.OCX, spr32x25.OCX, spr32x35.OCX (or a different .OCX file) or one of its dependencies not correctly registered" "A file is missing or invalid"
|
|
Card 715 View | HydraLIST (Standalone) | Test Point | None | Runtime Error | The computer had the Chinese language loaded as a second language The program could not open acsizefl.txt becuse it was messing with the way it read the ½” marks. To test eliminate the 1/2" marks in the acsizefl and try to open HydraLIST if it opens this is the problem. A side problem, it was uninstalled the HydraCALC program when the update is installed . runtime error 457 |
|
Card 714 View | HydraLIST (Standalone) | None | None | None | In the Nvidia GForce9600 Graphics card driver, some of the custom setup functions may cause this problem. Similar problem reported with Nvidia FX 540 & Gforce 5200 & Nvidia BFGtech Asylum GeForce4 4200 & Nvidia GForce9600 (see other cards) HydraLIST Closes |