Ribbon/Toolbar (Software) Button Function Error Type Description
Ribbon/Toolbar (Software) Button Function Error Type Description
Card 332 View Piping (AutoCAD Based) Size Pipe Setup None None

ATTDISP setting is wrong.

Card 300 View Piping (AutoCAD Based) Riser Nipple Setup None None

1. the v50 drawing does not have the block vp defined

Card 516 View Piping (AutoCAD Based) Edit Riser Nipples None None

Bad coding 2018 Riser Nipples V55

Card 337 View Piping (AutoCAD Based) Size Pipe Setup None None

Some pipe sizes have the diameter and length attributes switched in their order

Card 262 View Piping (AutoCAD Based) Size Pipe Setup None No Connectable Heads

incorrect setting for the autocad system variable ATTREQ

Card 118 View Piping (AutoCAD Based) Schedule Sizes None None

When attempting to open the HydraCALC pipe sizer in order to use the Pipe Scheduler in HydraCAD, you get an error indicating that a newer version of HydraCALC is required. It will indicate that v50.43 or newer is needed, but the user may be on a newer version already.

Card 1153 View Persistent Model (AutoCAD Based) Navis Model None None

When importing a Persistent Model into Revizto, none of the riser nipples are visible

Card 1152 View Persistent Model (AutoCAD Based) Navis Model None None

When reading a Persistent Model drawing in Revizto, the units are not correct

Card 1123 View Persistent Model (AutoCAD Based) Export None Error Writing

Exporting a Persistent Model gives the following message.  More than like the PM drawing gets saved anyway.

Cannot Save!  drawing path and filename might be OPEN.  Pleace (sic) close amd (sic) try again. 

*Should be "Please close and try again"

Card 467 View Persistent Model (AutoCAD Based) Export None None

The lines or mains do not get the pretty pipes applied. The layer is all lower case. Lines or Mains missing