Standalone HydraCALC (Location)

Button: Open Error Type: Runtime Error

Description:

When opening HydraCALC, a runtime-error 380 pops up.

Invalid property value

Solutions:


1.
Cause:

Bug

Solution:

This error occurs when a blank job is started then you attempt to edit the company data.  Open any calc job then attempt to edit the company data.


2.
Cause:

Possibly due to a missing file for the Company information.  None of the "company#.dat" files are present.

for example, " \HES\HydraCALC\VER50\Data\Setup\Company1.dat"

Solution:

Issue has been resolved in 50.55, but for now, get a copy of the file in question and copy it to this location.

\HES\HydraCALC\VER50\Data\Setup\