Standalone HydraCALC Sizer (Location)

Button: Open Error Type: Runtime Error

Description:

When trying to open HydraCALC Sizer, a 'run-time error 76', Path not found error pops up and the program doesn't open.

Solutions:

Cause:

Issue was found when the wrong drive was designated as the data path.  For example, the C:\ drive was being referenced, but the S:\ drive had the data

Solution:

*IMPORTANT*

It's important when editing the computer's System Registry you are care.  If you are uncomfortable doing so, please get someone with experience to make the changes below.

Using the System Registry, navigate to the following path;

Computer\HKEY_CURRENT_USER\Software\Hydratec\General\SetUp

Check the paths for DataPath, DocPath, ImportPath & ReportPath to make sure they're pointing to the proper DRIVE.  If your local drive is D:\, edit it as such.

When complete, collapse the paths then close out of the registry editor.

Updated: Sept. 19, 2022, 2:52 p.m. Created: April 29, 2020, 2:58 p.m.