Hydratec Inc.

Need to save a card for later?

Create a bookmark folder in your browser of choice (Chrome, Firefox...), and save individual cards in your bookmarks to view here later.

Standalone HydraLIST (Location)

Button: Test Point Error Type: Runtime Error

Description:

Mismatch Miscrosoft dll's Cause by one or all of the following: Update to Windows Adding or removing software Runtime Error 3447

Solutions:

Cause:

Run-Time Error 3447: The Jet VBA file (VBAJET.dll for 16-bit versions, or VBAJET32.dll for 32-bit versions) failed to initialize when called. Try reinstalling the applications that returned the error.

Solution:

Check version Number of each off the dll's listed below. If some are missing replace them with dll's of the same version Number. If you have some Visual Basic 5.0 and some from Visual Basic 6.0 replace the odd ones. DAO files are in the ProgramFiles/common/microsoftshare/DAO folder the remaining are in the system32 folder Visual Basic 5.0 Files and Version Numbers: DAO350.dll 3.50.3602.0 MSJet35.dll 3.50.3602.4 MSJInt35.dll 3.50.3602.5 MSJtEr35.dll 3.50.3602.0 MSRD2x35.dll 3.50.3602.0 MSRepl35.dll 3.50.3602.0 MSVCRT40.dll 4.10.6038 or later VB5DB.dll 5.00.3724 VBAJet32.dll 5.0.7122 Visual Basic 6.0 Files and Version Numbers: DAO350.dll 3.51.1608.0 ExpSrv.dll 6.0.8167 MSJet35.dll 3.51.0623.4 MSJInt35.dll 3.51.0623.0 MSJtEr35.dll 3.51.0623.0 MSRepl35.dll 3.51.0623.0 MSRD2x35.dll 3.51.0623.0 MSVCRT40.dll 4.21.0000 or later VB5DB.dll 6.00.8169 VBAJet32.dll 6.1.8167

Updated: Sept. 15, 2022, 2:49 p.m. Created: March 1, 2019, midnight