Hydratec Inc.

Need to save a card for later?

Create a bookmark folder in your browser of choice (Chrome, Firefox...), and save individual cards in your bookmarks to view here later.

Standalone HydraLIST (Location)

Button: Test Point Error Type: Runtime Error

Description:

mismatched dll's Runtime error 3445, 3445

Solutions:

Cause:

wrong version of msjet35.dll

Solution:

try installing MDAC2.5 Microsoft Knowledge Base Article - 192934 Or check that the files below are matched by checking the properties of each. Visual Basic 5.0 Files and Version Numbers: DAO350.dll 3.50.3602.0 MSJet35.dll 3.50.3602.4 MSJInt35.dll 3.50.3602.5 MSJtEr35.dll 3.50.3602.0 MSRD2x35.dll 3.50.3602.0 MSRepl35.dll 3.50.3602.0 MSVCRT40.dll 4.10.6038 or later VB5DB.dll 5.00.3724 VBAJet32.dll 5.0.7122 Visual Basic 6.0 Files and Version Numbers: DAO350.dll 3.51.1608.0 ExpSrv.dll 6.0.8167 MSJet35.dll 3.51.0623.4 MSJInt35.dll 3.51.0623.0 MSJtEr35.dll 3.51.0623.0 MSRepl35.dll 3.51.0623.0 MSRD2x35.dll 3.51.0623.0 MSVCRT40.dll 4.21.0000 or later VB5DB.dll 6.00.8169 VBAJet32.dll 6.1.8167

Updated: Sept. 20, 2022, 4:57 a.m. Created: March 1, 2019, midnight