AutoCAD Based HydraCALC (Ribbon/Toolbar/Location)

Description:

HydraCALC Load_Data Error Error loading file, confirm Filename and location are correct... <> Dialog Box HydraCALC

Solutions:

Cause:

Calc file has been formatted and rather than having many lines of data input (one for the CATEGORY and one for the DATA), all of the data has been truncated and all the ENTER keys deleted. You'll have one long line of input rather than multiple lines.

Solution:

Open the file using a text editor (ie. Notepad) and confirm that the file has been cleaned/scanned by having all the Carraige Returns removed. Was caused by the email server running the file through a virus scan or check and removing all the ENTERs. The only solution was to get the original sender to rename the file extension from .WXF to .TXT then resend the file. Once downloaded from email, rename the file extention back to .WXF [GAB 10/10/2016]

Updated: Sept. 20, 2022, 1:30 a.m. Created: March 1, 2019, midnight