Hydratec Inc.

Need to save a card for later?

Create a bookmark folder in your browser of choice (Chrome, Firefox...), and save individual cards in your bookmarks to view here later.

AutoCAD Based HydraCALC (Ribbon/Toolbar/Location)

Button: Utilities

Description:

Auto Program Load Error: Could not initiate process called for by... MiscFunc.exe

Solutions:

Cause:

1. HydraCalc v50 installed on something other than the C:\ drive causes the pipe/fittings table or pipe schedule or other utilities to not load. 2. Missing HydCalc.exe from the C:\HES\HydraCALC\Ver50\Programs folder

Solution:

1. In windows explorer, create an HES folder on the C:\ drive (just a folder, no files need to be in it) and the utilities will be able to be accessed. 2. Confirm the file is there and/or other pertinent files.

Updated: Sept. 19, 2022, 2:36 p.m. Created: March 1, 2019, midnight