Hydratec Inc.

Need to save a card for later?

Create a bookmark folder in your browser of choice (Chrome, Firefox...), and save individual cards in your bookmarks to view here later.

AutoCAD Based Launching HydraCAD (Ribbon/Toolbar/Location)

Description:

Bad update. These Files are missing system folder dependencies of HydexVB64 or HydexVB3: MFC100u.dll MSVCR100.dll MSVCP100.dll Because of this, no pass can be given nor does security work on any product. (64-bit products may work while 32-bit products don't or vice versa) Opening

Solutions:

Cause:

Bad update. These Files are missing system folder dependencies of HydexVB64 or HydexVB3: MFC100u.dll MSVCR100.dll MSVCP100.dll Because of this, no pass can be given nor does security work on any product. (64-bit products may work while 32-bit products don't or vice versa)

Solution:

RENAME THE FOLLOWING 3 Files (if they exist) in WINDOWS/SYSTEM32 & AGAIN IN WINDOWS/SYSWOW64: -MFC100U.DLL to MFC100U-OLD.DLL -MSVCR100.DLL to MSVCR100-OLD.DLL -MSVCP100.DLL to MSVCP100-OLD.DLL Then have them download the file posted on sharefile: 'HydexVB3-64Files.msi' Then have them double click it, there are no prompts. It just runs and fixes them.

Updated: April 1, 2024, 12:14 p.m. Created: March 1, 2019, midnight