Hydratec Inc.

Need to save a card for later?

Create a bookmark folder in your browser of choice (Chrome, Firefox...), and save individual cards in your bookmarks to view here later.

AutoCAD Based HydraCAD Residential (Ribbon/Toolbar/Location)

Button: Insert Head & Pipe References Function: Reference Points Error Type: Runtime Error

Description:

Runtime error 6: overflow Runtime Error 6,

Solutions:

Cause:

1. When finding heads and piping for reference points, everything in the drawing must be sorted and there is too much to sort through.

Solution:

1. The limit is 32,000 objects. Erase or wblock out parts of the background to get under 32,000 objects. In one instance, rebooting the computer helped get past the runtime error 6.

Updated: Sept. 19, 2022, 8:25 a.m. Created: March 1, 2019, midnight