Hydratec Inc.

Need to save a card for later?

Create a bookmark folder in your browser of choice (Chrome, Firefox...), and save individual cards in your bookmarks to view here later.

AutoCAD Based HydraCAD Residential (Ribbon/Toolbar/Location)

Button: Insert Head & Pipe References Function: Insert Head Error Type: Runtime Error

Description:

Runtime error 6: overflow Runtime Error 6,

Solutions:

Cause:

1. In the collecting of the data at the beginning of the process, there are more items to count than the limits of the program.

Solution:

1. Everything in the drawing (lines, blocks, hatch patterns, etc) gets counted and then sorted for use in the head reference/calculation process. Make your drawing have fewer objects (must be less than 32,000). In one instance, rebooting the computer helped get past the runtime error 6.

Updated: Sept. 14, 2022, 7:08 p.m. Created: March 1, 2019, midnight