Hydratec Inc.

Need to save a card for later?

Create a bookmark folder in your browser of choice (Chrome, Firefox...), and save individual cards in your bookmarks to view here later.

AutoCAD Based HydraCAD Residential (Ribbon/Toolbar/Location)

Button: Perform Hydraulic Calculations Function: Input Supply Pipe Data Error Type: Runtime Error

Description:

Runtime Error 13: Type Mismatch Runtime Error 13,

Solutions:

Cause:

1. Pex Linetype purged out of drawing

2. Missing Residual Pressure/Residual Flow from water supply

3. Foot (') mark used in supply piping lengths

Solution:

1. Insert drawing into new HydraNet template

2. add Residual pressure and Residual Flow to water supply.

3. remove the foot (') mark, length is automatically feet, inches are decimals.

Updated: Sept. 17, 2022, 1:18 p.m. Created: March 1, 2019, midnight