Need to save a card for later?
Create a bookmark folder in your browser of choice (Chrome, Firefox...), and save individual cards in your bookmarks to view here later.
Standalone HydraLIST (Location)
Description:
A main label prints in place of the welded line label
Problem happens with this specific set of circumstances:
1. Main ID is a single letter - i.e. D or <space>D
2. Main has more than one (1) piece of pipe in the ID - i.e. piece D.1, piece D.2, etc.
3. Welded line ID is the Main ID.Number of welded line - i.e. ID D.1, ID D.2, etc.
4. There is only one (1) piece of pipe in the welded line ID - i.e. D.1.1
5. A mains label creating custom program is on.
6. Pipe Sketch Summary 4 is on and Print Sketches in Best Cut Order is chosen.
When processing the list, Main ID's that have only one piece of pipe in the ID have the piece number dropped - i.e. ID D.1.1 becomes D.1 which is the same ID as Main D.1. This causes the first label (for Main D.1) to print twice.
Rename the welded Line ID to be a unique ID - so there is no conflict with the Main - i.e. D..1