Revit Based HydraCALC (Ribbon/Toolbar/Location)

Button: Hydraulic Calculations Function: Continue Error Type: 200 passes

Description:

This job has gone 200 or more passes without balancing.


Solutions:


1.
Cause:

Bad Density, Minimum End Head Pressure or Coverage Area data, causing the system pressure and flows not to be able to balance at junction points.

Solution:

Change the data to the correct data entries, and then re-run the calculation.


2.
Cause:

Reference point with more than 4 characters was created




Solution:

HydraCALC has a maximum of 4 characters for reference points, ensure reference points are 4 characters or fewer


- Thanks Brian S!