Hydratec Inc.

Need to save a card for later?

Create a bookmark folder in your browser of choice (Chrome, Firefox...), and save individual cards in your bookmarks to view here later.

AutoCAD Based Piping (Ribbon/Toolbar/Location)

Button: Schedule Sizes

Description:

When attempting to open the HydraCALC pipe sizer in order to use the Pipe Scheduler in HydraCAD, you get an error indicating that a newer version of HydraCALC is required. It will indicate that v50.43 or newer is needed, but the user may be on a newer version already.

Resolved in: HYD-50.50

Solutions:

Cause:

Bad Registry Entry

Solution:

A. Close HydraCAD and HydraCALC, re-install the update for HydraCALC v50.3.50 and try again. This will fix the registry entry.

OR

B. If the user can edit their registry, they'll want to edit the key;

[HKEY_CURRENT_USER\SOFTWARE\Hydratec]

Check the STRING [HydracalcMinorVersion].

Call Hydratec for more details. (GAB 4/01/15, 6/11/16)

Updated: Aug. 14, 2023, 2:25 p.m. Created: March 1, 2019, midnight