Hydratec Inc.

Need to save a card for later?

Create a bookmark folder in your browser of choice (Chrome, Firefox...), and save individual cards in your bookmarks to view here later.

AutoCAD Based Calculations (Ribbon/Toolbar/Location)

Button: Calc Check Ups

Description:

Duplicate Reference Points with jump detour

Solutions:

Cause:

After running checkups, you get a message indicating the reference points used on a jump detour is duplicated. Erasing and reinserting them still reports the error

Solution:

Turn off the piping layers and HYD layer. You should see a green dot at the location of the two jump detours. Erase the green dots (or use the DL command to erase *all* of the green dots). Try checkups again. GAB 9/02/14

Updated: Jan. 29, 2024, 10:02 a.m. Created: March 1, 2019, midnight