Ribbon/Toolbar (Software) Button Function Error Type Description
Ribbon/Toolbar (Software) Button Function Error Type Description
Card 138 View Calculations (AutoCAD Based) Start Autocalcs Calc Area # Missing File

 

File name asked for does NOT exist

FitExch.dat 1A.1

Card 70 View Calculations (AutoCAD Based) Start Autocalcs Calc Area # Duplicated Hydraulic Ref Point

 

Step 1a.10 - "Attaching Node 2 Elevations" User ID Duplicated Dwg ID Dup for User ID

Duplicated hydraulic ref points

 

 

Card 75 View Calculations (AutoCAD Based) Start Autocalcs Calc Area # None

Drawing seems fine with no errors but opens to a blank HydraCALC screen

Card 141 View Calculations (AutoCAD Based) Start Autocalcs Calc Area # Message Box

System seems to hang at this step, but eventually shows the error;

Hydraulic Calculation - The system flow demand of ####.## exceeds the maximum rated flow as indicated in the Pump Curve for the pump with the inlet of PI and outlet of PO.

 

The calculation will not continue Calculation failed for an unknown reason

May not be 1a.3 or 2.3, could be anywhere along here.

Card 51 View Calculations (AutoCAD Based) Start Autocalcs Calc Area # None

Water supply test point not connected to a pipe. Reinsert water supply\test point

Card 81 View Calculations (AutoCAD Based) 3-D Flow Diagram None None

3D Flow diagram missing direction arrows and flows

Card 56 View Calculations (AutoCAD Based) Start Autocalcs Calc Area # None

After calc Area # is picked, dialog box runs through gathering information and closes with message "Failed to create file to send to calcs....Exiting"

Card 61 View Calculations (AutoCAD Based) Start Autocalcs None Runtime Error

Runtime Error 457 - This key already associated with an element of this collection

Card 42 View Calculations (AutoCAD Based) Start Autocalcs None None

"Hydraulic Engine not responding" and then an "Error 62 input past end of file" usually happens on 2nd area run through

Card 63 View Calculations (AutoCAD Based) Start Autocalcs None Unhandled Exception

Unhandled Exception: Index was outside the bounds of the array

Card 143 View Calculations (AutoCAD Based) Start Autocalcs None None

x Zero length pipes found in system model YES will cancel... No will allow...

Card 181 View Listing (AutoCAD Based) Start Autolist None Dao Error

Call from 'AutoList::CleanupDatabase (hangerHeaderDB)' DAO Error The changes you requested to the table were not successful.... DAO error

Card 254 View Listing (AutoCAD Based) Start Autolist None None

Error is V50 Drops

Card 176 View Listing (AutoCAD Based) Start Autolist None Failed To Launch

"AutoLIST Failed!... Please run Listing CheckUps"

 

This message is shown when running the AutoLIST process, but checkups didn't find any errors AutoLIST Failed

Card 147 View Listing (AutoCAD Based) Start Autolist HydraList opens Runtime Error

Runtime Error 5 when opening HydraLIST during the AutoLIST process. Error 5

Card 724 View HydraLIST (Standalone) Process None Runtime Error

Run-time error 484

Problem getting printer information from the system.  Make sure the printer is set up correctly

Hydraview cannot read the printer drivers. Could be a printer, copier, scanner, fax machine.

Card 335 View Listing (AutoCAD Based) Start Autolist None None

Possibly a folder marked as "hidden" in Autocad.

Card 62 View Calculations (AutoCAD Based) Start Autocalcs None None

Area # section is blank or missing remote areas in the AutoCalc Setup dialog box. Area number is not recognized

Card 133 View Calculations (AutoCAD Based) Start Autocalcs None None

The specified remote node does not have a k-factor. Please fix your input. On Pass 1 Calculation Failed for an unknown reason.

Card 58 View Calculations (AutoCAD Based) Start Autocalcs None None

Step 5a.3b - Hangs up reordering Pipe Paths