All Cards
* On smaller devices swipe left to view hidden table data
| Ribbon/Toolbar (Software) | Button | Function | Error Type | Description | ||
|---|---|---|---|---|---|---|
| Ribbon/Toolbar (Software) | Button | Function | Error Type | Description | ||
| Card 278 View | 3D Modeling (AutoCAD Based) | Show System Model | None | None | There is a frozen and / or locked HydraCAD layer. or RNs with 0-0 length |
|
| Card 131 View | Calculations (AutoCAD Based) | Start Autocalcs | Calc Area # | Runtime Error | After clicking the 'Calc Area 1' button, the Runtime Error 5 immediately pops up. Run-time Error 5, Invalid Procedure Call or Argument |
|
| Card 132 View | Calculations (AutoCAD Based) | Start Autocalcs | None | Runtime Error | Transfer to HydraCALC Step 1a.2 Loading Fitting Exchange Data Run-time 9 Runtime 9 Run-time Error 9 Runtime Error 9 |
|
| Card 120 View | Calculations (AutoCAD Based) | Start Autocalcs | None | Runtime Error | Run-time error 76 Path not found Runtime Error 76 |
|
| Card 551 View | Build 3D Risers (AutoCAD Based) | Insert Pump | None | None | Extra line of input was entered into the VPUMP.DAT file found here; \HES\HydraCAD\Ver50\Programs\3DFTGS Unhandled Exception Insert Pump n/a |
|
| Card 94 View | Calculations (AutoCAD Based) | Calc Check Ups | None | None | Upon starting the Checkup command for AutoCalc, the command starts but stops. The Command Prompt says; "Initializing... Checking to make sure heads are in the right layer...bad argument type: stringp nil" As a side note, the user's drawing had multiple repeat head definition boxes (blue boxes in ACC1 layer). These were cleaned up (deleted) and the heads redefined. The AUDIT command was run after the cleanup |
|
| Card 507 View | Sprinklers (AutoCAD Based) | Insert Sprinkler | None | None | Missing application n/a Choose Part Number n/a |
|
| Card 330 View | Calculations (AutoCAD Based) | Figure Head Area | None | None | Figure Head Area cannot find the APQ block in the drawing's block table. **Possible there's a missing registry entry** Dialog box 54.04 |
|
| Card 184 View | Listing (AutoCAD Based) | Start Autolist | None | None | AutoList begins and just cycles, does not complete and open HydraList. sits spins loops finishes cycles |
|
| Card 174 View | Listing (AutoCAD Based) | Start Autolist | None | None | One or more objects in this drawing cannot be saved to the specified format. The operation was not completeed and no file was created. |
|
| Card 388 View | Calculations (AutoCAD Based) | Figure Head Area | None | None | The current text STYLE is using a smaller font n/a drawing area v52 |
|
| Card 173 View | Listing (AutoCAD Based) | Start Autolist | None | None | Change requested in table not successful. Change data in fields or fields containing duplicate data. Error 3022 |
|
| Card 115 View | Calculations (AutoCAD Based) | None | None | Runtime Error | Runtime Error 380. After raising to 3D then then selecting the pipe types to apply the schedule to, the error message pops up when the HydraCALC Pipe Scheduler tool is supposed to appear. Press OK at the error message then ESC when the command asks to select a pipe. |
|
| Card 97 View | Calculations (AutoCAD Based) | Reference Points | None | None | 1. Inserting a hydraulic reference point doesn't erase an existing ref point at the same location 2. New ref points in HydraCALC are not using the values of the HYD ref points. |
|
| Card 498 View | Build 3D Risers (AutoCAD Based) | Insert Fitting Via HydraList | None | None | Dialog box is not appearing |
|
| Card 516 View | Piping (AutoCAD Based) | Edit Riser Nipples | None | None | Bad coding 2018 Riser Nipples V55 |
|
| Card 178 View | Listing (AutoCAD Based) | Start Autolist | None | Unhandled Exception | Unhandled exception E was erased Unhandled exception |
|
| Card 256 View | 3D Modeling (AutoCAD Based) | Check Elevation | None | None | Bad support path or cad not configured for V50.
|
|
| Card 369 View | Calculations (AutoCAD Based) | Figure Head Area | None | Unhandled Exception | When returning from 3D view, the drawing's current layer becomes Layer 0 (zero). Unhandled Exception Dialog Box v51 v52 |
|
| Card 583 View | All products (Security and Licensing) | None | None | Error 99 | Error 99. Hydratec Security Versioning Error. You do not have access to this version of this product.
|
|
Page: