Hydratec Inc.

AutoCAD Based (Launching hydracad)

Total: 105

Page:

* On smaller devices swipe left to view hidden table data

Ribbon/Toolbar (Software) Button Function Error Type Description
Ribbon/Toolbar (Software) Button Function Error Type Description
Card 310 View Launching HydraCAD (AutoCAD Based) None None None

These ARX errors can occur when trying to open a DWG file containing new type of objects (objects coming from a newer version).

Card 305 View Launching HydraCAD (AutoCAD Based) None None None

Unable to double click for text editing

Card 303 View Launching HydraCAD (AutoCAD Based) None None None

trying to underline or overline Mtext Note: this fix will require the workspace to be recreated Acad 2009

Card 299 View Launching HydraCAD (AutoCAD Based) None None None

UCS is out of whack or the clockwise option is checked in units dialog Tagging

Card 292 View Launching HydraCAD (AutoCAD Based) Paper Space None None

In a paper space viewport, certain blocks or dimensions do not appear, even though the layer is ON and set to Plot in Current Viewport

It may appear as if the layer is not showing up, but it is really certain items in the layer

Card 284 View Launching HydraCAD (AutoCAD Based) None None None

Copy and Paste takes forever, slow process

Card 271 View Launching HydraCAD (AutoCAD Based) None None None

Install think enabler is on computer Installation

Card 268 View Launching HydraCAD (AutoCAD Based) Purge None Fatal Error

A sprinkler head is drawn in space and is not connect to anything. When the drawing is raised a Hydrafitting (cap) is placed on the head. if the purge command is invoked it will cause a fatal error. Fatal error Purge V51

Card 264 View Launching HydraCAD (AutoCAD Based) Save None None

Something has disabled the QSAVE. Unknown cause but usually happens after AutoCalc Command in progres Command Prompt AutoCAD 2009,2010

Card 260 View Launching HydraCAD (AutoCAD Based) None None Security Error

When opening HydraCAD, you only receive this error message and not a HydraKEY error with the golden X.  If you receive a HydraKEY error, search for the linked HydraCARD in that message box as it takes priority.

 

Security Error: One of the following conditions is possible

HydraCAD is unable to function under these conditions.

  • Lock database needs updating in HydraKEY
  • Accounting flag on your account
  • Hardware lock not plugged in
  • Extra ACAD.RX file found in folder in Support File Search Path
  • Sentinel driver is missing
  • InstallPath registry item set to wrong drive

After AutoCAD opens, press F2 to view the command prompt, see if the text below appears.  If yes, see solution 1.

Could not find file HCAD_ENV.INI

Is 2024; error: no function definition: PRINTEM

 