| Ribbon/Toolbar (Software) | Button | Function | Error Type | Description | ||
|---|---|---|---|---|---|---|
| Ribbon/Toolbar (Software) | Button | Function | Error Type | Description | ||
| Card 310 View | Launching HydraCAD (AutoCAD Based) | None | None | None | These ARX errors can occur when trying to open a DWG file containing new type of objects (objects coming from a newer version). |
|
| Card 305 View | Launching HydraCAD (AutoCAD Based) | None | None | None | Unable to double click for text editing |
|
| Card 303 View | Launching HydraCAD (AutoCAD Based) | None | None | None | trying to underline or overline Mtext Note: this fix will require the workspace to be recreated Acad 2009 |
|
| Card 299 View | Launching HydraCAD (AutoCAD Based) | None | None | None | UCS is out of whack or the clockwise option is checked in units dialog Tagging |
|
| Card 292 View | Launching HydraCAD (AutoCAD Based) | Paper Space | None | None | In a paper space viewport, certain blocks or dimensions do not appear, even though the layer is ON and set to Plot in Current Viewport It may appear as if the layer is not showing up, but it is really certain items in the layer |
|
| Card 284 View | Launching HydraCAD (AutoCAD Based) | None | None | None | Copy and Paste takes forever, slow process |
|
| Card 271 View | Launching HydraCAD (AutoCAD Based) | None | None | None | Install think enabler is on computer Installation |
|
| Card 268 View | Launching HydraCAD (AutoCAD Based) | Purge | None | Fatal Error | A sprinkler head is drawn in space and is not connect to anything. When the drawing is raised a Hydrafitting (cap) is placed on the head. if the purge command is invoked it will cause a fatal error. Fatal error Purge V51 |
|
| Card 264 View | Launching HydraCAD (AutoCAD Based) | Save | None | None | Something has disabled the QSAVE. Unknown cause but usually happens after AutoCalc Command in progres Command Prompt AutoCAD 2009,2010 |
|
| Card 260 View | Launching HydraCAD (AutoCAD Based) | None | None | Security Error | When opening HydraCAD, you only receive this error message and not a HydraKEY error with the golden X. If you receive a HydraKEY error, search for the linked HydraCARD in that message box as it takes priority.
Security Error: One of the following conditions is possible HydraCAD is unable to function under these conditions.
After AutoCAD opens, press F2 to view the command prompt, see if the text below appears. If yes, see solution 1. Could not find file HCAD_ENV.INI Is 2024; error: no function definition: PRINTEM
|
|