Standalone HydraLIST (Location)

Button: Process Error Type: Runtime Error

Description:

Error occurs when trying to process a list created by AutoLIST. This may have happened when LIST HANGERS BY LINE NUMBER was checked in the AutoLIST Setup. Runtime Error 3022

Solutions:

Cause:

Change requested in table not successful. Change data in fields or fields containing duplicate data.

Solution:

Solution 1 - Review the hanger inputs and delete the blank hanger sections. Solution 2 - Review the hanger inputs and resave them. HydraLIST will automatically fix the header record. See also AutoLIST Error Cards for Error 3022.