Hydratec Inc.

Need to save a card for later?

Create a bookmark folder in your browser of choice (Chrome, Firefox...), and save individual cards in your bookmarks to view here later.

Standalone HydraLIST (Location)

Button: Test Point Error Type: Runtime Error

Description:

The system was set to force an update of the setup data when entering the program. the first open system was active and caused the data base to be locked. the sencond openning tried to up data which was already open the the first system and the error occured. runtime error 75 75

Solutions:

Cause:

Run time error 75 openning a second session of HydraLIST

Solution:

turn off force load when the computer is set to automatic update sof the database go to Utilities Alter Master Data location turn off force load data always exit hydralist or don't open the sencond session open first session of hydralist and open a project open scond session of hydralist and open the second project

Updated: Sept. 20, 2022, 5:07 a.m. Created: March 1, 2019, midnight