Hydratec Inc.

Need to save a card for later?

Create a bookmark folder in your browser of choice (Chrome, Firefox...), and save individual cards in your bookmarks to view here later.

Standalone HydraLIST (Location)

Button: Open Function: Opening Error Type: Runtime Error

Description:

Bad or missing data in ACSIZEFL.TXT or HISTORY.LST files

Runtime Error 62 62

Solutions:

Cause:

Input past end of file

Solution:

In Windows Explorer, navigate to; C:\HES\COMMON\VER50 and edit/open these files using Notepad.

Ensure the last line of data in the HISTORY.LST file contains the text EOD

If HISTORY.LST is a blank file, type EOD as the first/last line of text then save and close the file.

 

Make sure the ACSIZEFL.TXT file has data in it, the last line should start with 7&  If you're not sure, get the file from someone else in the office and replace yours with theirs.

Updated: June 30, 2023, 2:33 p.m. Created: March 1, 2019, midnight