Standalone HydraCALC (Location)

Button: Open Error Type: Runtime Error

Description:

When opening HydraCALC, you get the error "Invalid Property Value" Runtime 380

Solutions:


1.
Cause:

User did not install V50, just ran update from website. Files missing from Hes\HydraCALC\Ver50\Data\Setup folder

Solution:

Run full install of V50


2.
Cause:

User was opening multiple calc files (.WXF) by highlighting them in Windows File Explorer then pressing ENTER to open many in many HydraCALC sessions 

Solution:

This method is not recommended.  It's better to first open multiple HydraCALC sessions first, then in each one open the .WXF file

Solution was to re-install HydraCALC.  During the re-install, choose the REPAIR option if the window opens.