AutoCAD Based HydraCALC (Ribbon/Toolbar/Location)

Description:

A Stop Statement has occurred - program must close

Solutions:

Cause:

A nominal diameter has been entered with a pipe type that has an internal diameter of 0 in that size (which means they don't make that size). The calculation will not open after it crashes. An issue in v50.1.9 or earlier.

Solution:

1. Update to latest HydraCalc. 2. Open the calc file in notepad and add EOD under the very last line of input. The calc will be able to be reopened but some information will be lost.

Updated: Sept. 20, 2022, 5:09 a.m. Created: March 1, 2019, midnight